Build Your Garage Sub Panel Dig an 18-inch deep trench for the outdoor electrical wire, which you will run from the main panel box to the garage sub panel. Use 1 1/4-inch PVC conduit for a 100-amp sub panel or 1-inch PVC conduit if the sub panel is 50 amps or less.

Do I need conduit for sub panel?

Moderator. Unless you area requires conduit for wiring in dwelling units there is no NEC issue with running a cable as a feeder. It must be a 4 wire cable to the sub panel.

What kind of cable do I need for a sub panel?





This is typically a three-wire cable with three insulated conductors plus a bare copper ground wire. The cable must have a wire gauge sufficient to the amperage of the subpanel—a 100-amp subpanel requires #4 copper wires or, more commonly, #2 aluminum wires, for example.

Do garage wires need to be in conduit?

Many garages contain one or more walls made of concrete or already drywalled. Cable installed on these exposed surfaces has to be protected by conduit. We show EMT (electrical metallic tubing; Photo 7), but you can also use rigid PVC conduit.

What size conduit do I need for 100 amp sub panel?

What Size Conduit You Need for 100 Amp Service. A 100 amp service will need a minimum of 1.25 inches, schedule 40 or 80 PVC grey electric conduit.

How do you wire a sub panel in a garage?

Quote from the video:
Quote from Youtube video: If you're doing a sub panel. You want to make sure the power is off got my wire going to power the outlet. And two switches. And then i've got my 10 2 wire. That's coming from the main panel.

How do you set up a subpanel to a detached garage?





Dig an 18-inch deep trench for the outdoor electrical wire, which you will run from the main panel box to the garage sub panel. Use 1 1/4-inch PVC conduit for a 100-amp sub panel or 1-inch PVC conduit if the sub panel is 50 amps or less. Run the conduit from the garage to the main panel box.

What size wire do I need to feed a 50 amp sub panel?

6 AWG Wire

6 AWG Wire Used For 50 Amp Service.

What wire do I need for a 60 amp subpanel?

In short, the wire size for a 60 amp sub-panel 150 feet away is 3 AWG gauge wire.

Does a subpanel need a ground rod?



Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building.

Can you run a 100 amp sub panel off a 100 amp main panel?

Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

What size electrical conduit should I use?

One wire: maximum fill is 53% of the space inside a conduit. Two wires: maximum fill is 31% Three wires or more: maximum fill is 40% of the conduit’s total available space.



How to size conduit for cable.

Number of wires Insulation type Gauge
4 THHN 8 AWG
2 THW 4 AWG



Can I run a 100 amp sub panel off 200 amp main?

Can you add a 100 amp breaker to your main panel? Yes you have 12 slots the double pole breaker will only take 2 slots.

Does a garage subpanel need a main breaker?

A main breaker on a sub-panel is not necessary because this is in the same building (if you are in a different building then NEC 225.31, 225.32, 225.33 apply). That said, having a main breaker in the sub-panel is also acceptable.

How do you hook up a 100 amp subpanel to a garage?

Quote from the video:
Quote from Youtube video: From so and here's where the 100 amp breaker goes and then we'll drop wire down run it all the way across in through there.

Does a subpanel in a detached garage need a ground rod?



The detached structure is required to have its own Grounding Electrode System (GES) i.e. ground rods. The subpanel in the detached structure will have its grounds and neutrals separated.

Does a 60 amp subpanel need a ground rod?

In the same building or attached building no ground rod is required just hot hot neutral ground, with ground and neutral being isolated from each other in the sub panel.

Why does a subpanel need 4 wires?

The neutral and ground are not bonded in the subpanel. In this setup if a hot wire coming in contact with the non-current carrying parts of the electrical system, (outlet covers, panel covers etc), the 4th ground conductor will provide a low resistance patch back to the source tripping a breaker.

Why do you not ground a subpanel?

So, why do you separate the ground and neutral in a subpanel? Because when we bond them together, it gives your neutral wire (the one carrying electrical currents BACK to the source) multiple pathways. That’s how the chassis of some equipment will become energized.

Do you use a bonding screw on a subpanel?



Quote from the video:
Quote from Youtube video: But in this case. The bonding screw is that green headed screw right there. So that screw just simply threads through the neutral bus.

How high off the ground does a sub panel have to be?

All electrical panels must have a minimum of 36 inches of clearance in front of the panel, 30 inches of clearance across the face of the panel, and a minimum of 78 inches above the floor from the top edge of the panel.