What size service wire do I need for a 100 amp service?

For 100 AMP service, you’ll need a #4 AWG copper wire or #2 AWG aluminum or copper-clad wire. Make sure to limit your voltage drop to 3% regardless of distance.

What wire do I use for a 100 amp box?





The cable must have a wire gauge sufficient to the amperage of the subpanel—a 100-amp subpanel requires #4 copper wires or, more commonly, #2 aluminum wires, for example. (Aluminum is often used for feeder cables because the cost is typically much lower than that of copper wires.)

What size wire do I need to run 100 Amp Service 150 feet?

2/0 AWG wire

100 amp service 150 feet away from the sub panel requires #00 AWG wire (also known as 2/0 AWG wire). This wire has a median ampacity of 175 amps; more than enough than the required minimum 162.5 ampacity.

What size wire is needed from meter to panel?

Electrical wire





Based on the current and voltage rating of the meter and breaker, #4 size AWG copper wire is the highly suggested type and size of wire. This is to provide efficiency in conductivity; it will also prevent unnecessary loss of power, short circuit, damages, even wiring faults that may lead to dangers.

What wire size do I need to go 100 feet for a 100 amp service to a workshop?

For a 100 ampere circuit, the conductors will likely be required to be 3 AWG copper or 1 AWG aluminum.

Will #2 wire fit in a 100 amp breaker?

A 100 amp sub panel wiring size requirement is #4 for copper wires and #2 for aluminum wires.

Can you run a 100 amp sub panel off a 100 amp sub panel?

Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

What size wire do you use from the meter box to the breaker box for to 200 amp service?



The Quick Answer

For a 200 amp service, you’ll need: #2/0 copper wire, or. #4/0 aluminum or copper-clad aluminum wire.

How many wires do I need for a 200 amp service?

Wire Sizes for 200 Amp Service

Service or Feeder Rating Copper Wire Minimum Conduit Size
200 Amps #2/0 AWG 1.5 inch
225 Amps #3/0 AWG 1.5 inch
250 Amps #4/0 AWG 2 inch
300 Amps 250 kcmil 2.5 inch

What size wire do I need for a 100 amp underground 300 ft run?



for 300 feet for 100 amp rated service I would use Aluminum direct burial 1/0-1/0-1/0-1/0, the forth can be as low as #4 for the ground (but also in conduit, even if in conduit must still be rated underground wire and required by code also) Also note the size wire the breaker can handle, cannot cut strands to make fit, …

How far can you run #2 aluminum wire?

Example calcuation 2 – Aluminum Wire, 1 phase power

Cable run: 400 ft. 1 conductor per phase utilizing a 1000 kcmil Aluminum conductor installed Direct Buried will limit the voltage drop to 2.61% or less when supplying 194 amps for 400.0 feet on a 240 volt 1 phase system.

What is #2 aluminum wire?

#2 Stranded Aluminum XHHW-2 Wire



XHHW-2 are primarily used in air duct, conduit or recognized raceways for services, feeders and branch circuit wiring as specified in the National Electrical Code.