How do you test a fan relay on an air handler?

Quote from the video:
Quote from Youtube video: Set your meter to the lowest resistance level. And you should read approximately 70 80 ohms of resistance. We're showing 79 it's good now between the other side five and six should show closed two.

What causes a furnace fan to stop working?





If the fan does not start, you have a wiring issue (circuit breaker trips) or motor problem (circuit breaker does not trip). While your thermostat may be at fault, only an HVAC technician can diagnose and remedy the issue correctly. Time to call in the experts!

What does an air handler relay do?

In a blower motor, the relay supplies the power that allows the fans to circulate warmed air. Essentially an on/off switch, the blower motor relay’s reactions start and end the heating process in HVAC systems by controlling the flow of current between the power source and the motor.

Does the outside fan run when heat is on?

Your thermostat is set for “heat”, warm air is coming from your vents, and everything in your heating system seems to be working perfectly – except for the fact that your outdoor air conditioner unit is running. Why? The answer is simple: your outdoor unit is a heat pump.

How do I know if my blower motor relay is bad?

If you have a faulty blower motor, you may experience low airflow from the vents, even when the fan is on high. There will be no air coming from the vents if your fan isn’t working due to a bad blower motor resistor. Blown relay circuit fuses or melted relays are more serious signs of a bad blower motor relay.

How much is a blower motor relay?





around $50 to $80

The blower motor pushes air out of the vents and into your car. The blower motor is operated by an electrically operated switch, called a relay. If the relay fails, the motor’s fans will not blow conditioned air into your car. Fixing the relay usually costs around $50 to $80.

How do you reset a furnace fan?

Locate the reset button on the furnace and press it to reset the furnace. It is usually located inside the blower compartment on the side of the blower motor. Be cautious as the housing may be hot. If the button is popped up, press it down.

Where is the fan limit switch located?

Your fan limit switch is located inside the furnace panel cover, usually near the upper right corner. The fan limit switch is responsible for turning the blower on and off at the appropriate times.

Why is my air handler not working?



First make sure there is power to the indoor unit and that a switch or breaker isn’t off. Some indoor units (Heat Pumps) have breakers right on the Air Handler itself. But also check the main breaker panel. Some units have a shutoff switch on the side of the unit or an Emergency Switch located on a wall.

How do I know if my air handler is bad?

4 Ways to Tell If Your Air Handler Is Bad in Orlando, FL

  1. Fan Unit Problems. The fan or the blower in your air handler unit is responsible for blowing conditioned air through the ductwork throughout your home. …
  2. Condensate Pan Leaks. …
  3. Dirty AC Blowers. …
  4. Blower Motor Failure.


How do I reset my air handler?



Turning Off & Resetting Your AC Unit in 4 Simple Steps

  1. Shut it Off. First, turn off your AC before resetting the thermostat. …
  2. Get to the Circuit Breaker. So far, so good. …
  3. Wait 30 Seconds. After turning off the circuit breaker linked to the AC unit, wait for a full minute. …
  4. Turn it Back On.