How far can a toilet be from the main vent stack?

6 feet





According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.

What fall do you need on a soil pipe?

1 in 40

What is the recommended fall for a soil pipe? The minimum fall for a waste pipe is 1 in 40. The maximum fall is 1 in 110 (apart from vertical pipes but that’s a different story). So pipes with a gradient between 1 in 40 and 1 in 110 should have adequate flow to prevent blockages from occurring.

How far can a drain be from a vent?

For a 1 ½-inc pipe the vent should be 42 inches away at the most while a 2-inch pipe must have a maximum distance of 5 feet. For pipes that have a diameter of 3 inches the distance is 6 feet and for a 4-inch pipe the most it should be away from the vent is 10 feet.

Can you run a drain into a vent pipe?





In the case of a tub that is close to a stack, its drain can empty into a pipe that also serves as a vent. For a freestanding sink, code might allow a loop vent. If reventing is difficult and wet venting isn’t allowed, you might have to install a separate vent pipe through the roof.

Can a toilet and shower share a vent?

So yes the shower can also be vented by the wet vent along with the toilet. There is one major stipulation when wet venting multiple fixtures when a toilet is one of them: the toilet must be the last fixture connected to the wet vent.

Can 2 toilets share the same vent?

Most houses have more than one toilet, and if they are on the same side of the house, their waste lines can usually tie into the same stack. If they are on opposite sides, however, each may need its own stack. Since the stacks must be vented, this would mean two vent openings on the roof.

Can you put a 90 in a vent pipe?

Do not use the sharp, 90-degree vent elbow designed for venting above the water line. Note: You may have vent piping, but you still cannot use the tight 90-degree elbow — sometimes called a “vent elbow” — if the joint is below the water level, which is usually at the level of the sink. 3.

Can a sink and shower share a vent?



You can put the sink drain into the shower drain. 2. If the vent is less than 5 feet from the other fixture, they can share it.

How many fixtures can a 2 inch vent handle?

The Plumbing Code states that a vent can handle 24 fixture units. A bathroom sink of 1.0 F.U., a bathtub of 2.0 F.U., and a shower of 2.0 F.U.

Does a washing machine drain need a vent?

All plumbing fixtures—including washing machines—must be vented. Improperly vented drains can be sluggish and noisy, and can emit hazardous fumes. Properly vented drains allow the P-trap to do its job: prevent sewer gases from escaping into your home.

How far can a shower be from a vent stack?



The connection between the fixture drain and the horizontal drain and vent pipe is the only vertical pipe of a combination drain and vent system. 8 feet is the maximum vertical distance.

Does every sink drain need a vent?

Every sink needs a sink vent. A plumbing fixture like a sink can not function properly without a sink vent.

Does plumbing vent go before or after trap?

The simple answer is if your trap from the fixture cannot see the vent then it is installed wrong. We must always keep the vent connection above the trap weir to prevent siphoning and keep proper pressures on both side of the trap.

How far can a vent be from a floor sink?

The vent connection must extend up to a minimum of 6 inches above the rim of the floor sink before offsetting. As per standards, the diameter of the vent must be half of the floor sink’s pipe itself. A 1 ½ inch diameter is a minimum for vent pipes.

How many plumbing vents can be tied together?



You can usually tie up to eight fixtures to a single stack, but local codes differ, so it’s a good idea to check.

Can two plumbing fixtures share a vent?

Yes they both can share a vent. The distance between yours is 4′ if I read it correctly so you are well within the distance between the vent and fixtures so you should be golden unless your local code has some bizarre requirements.

Can you offset a vent stack?

For this system to function effectively there cannot be any offsets in the waste stack portion. Once the highest branch interval is connected to the stack, the vent portion may contain offsets, provided such offsets are at least 6 inches above the branch interval connection.