How do you run electrical wire through a finished ceiling?

Quote from the video:
Quote from Youtube video: Risk i would so much rather cut a little hole. Um i just i just you run the risk of going pushing too much angle and going through the outside.

How do I run conduit through finished walls?





Quote from the video:
Quote from Youtube video: To cut a notch cut. Into the drywall at the location of the wall block. Then use a sharp chisel. And a hammer to cut a 3/4 inch wide by 1 inch deep notch in the fire block as a conduit for the cable.

How do you hook up a 100 amp subpanel to the main panel?

Quote from the video:
Quote from Youtube video: Cover then of course we're going to need our feeder wire coming from our main panel over to our sub panel and in this case we're going to be running three gauge copper.

Can you run a 100 amp sub panel off a 100 amp main panel?

Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

How do you run a wire through the ceiling without an attic?

Quote from the video:
Quote from Youtube video: I'm going to open up the wall on the other side because there's a bathroom on this side. I've already brought my ladder in here. So this is just the other side of the wall. So i'm going to open it up

Can you run Romex on top of ceiling joists?





There is nothing wrong with running your electric on top of joists but you really should try to do it in areas that aren’t going to be exposed to any foot traffic. If you need to go parallel then simply run them a few inches down on the side of a joist.

How high should electrical wires run in walls?

We usually run them close to the height that the receptacles are to save wire many of the homes I have wired run from 8” to 24” with most 12-16” I like the taller ones because boring the holes through the studs is easier a little higher, just make you bore your hole in the center of the board so there is 1-1/4” or more

How far can 12 gauge wire run?

You can run a 12 gauge wire up to 70 feet on a 15 amp circuit. That number drops to 50 feet if you run 12 gauge wire on a 20 amp circuit.

How do you run PVC electrical conduit?

Steps to Connecting the Conduit to the Electrical Box

  1. Power off. First, the number one safety protocol before working on electrical maintenance is switching off the main breaker. …
  2. Cut the conduit. …
  3. Smoothen it out. …
  4. Install the fittings. …
  5. Apply the PVC cement. …
  6. Connect the pipe and the box. …
  7. Fish the wirings through.



Can you run wire through ceiling joists?

Running electrical wire through the channel between ceiling joists is generally easiest. In addition, your light fixture may require mounting to a ceiling joist or to two short blocks nailed between the joists. Trace and mark the fixture hole and cut out with a drywall saw, utility knife or reciprocating saw.

How do you install a junction box in a ceiling?

Quote from the video:
Quote from Youtube video: Once you have the wire in the box you're going to push. The box back into the ceiling. And the box will have this particular one has three clips. So as you screw. The screws in the clips.

Can you run wires over joists?



The best way to run wires along ceiling joists is to use a running board, spacing the wires evenly with electrical staples. This is for running wires in the direction of the joists or perpendicular to them. If there is no space, you can bore holes in very specific places to run wires through.

Does Romex need to be stapled?

Quote from the video:
Quote from Youtube video: About is not stapling romex on edge these are flat cables. So you need to put the cables down flat on top of each other and staple on top of that.

Can Romex be stapled to the bottom of floor joists?

You can staple the wire on top of this wood either with the help of a staple gun, hammer some nails and bend them, or even use screws to fasten the wire to the wood. So, in essence, Romex can be stapled to the bottom of floor joints without any issues.

Can you zip tie electrical wires together?

Electrical zip ties can be used to keep any sort of electric wires properly bundled and out of the way. Whether you need to keep your computer wires tied, an entire server tied down or any other large items keep neat and tidy, cable zip ties are the easy and economical way to get the job done quickly and easily.

How far from a box must Romex be secured?



Article 336-18 stated that cable must be secured in place at intervals not exceeding 4.5 feet (1.37 m) and within 12 inches (305 mm) from every cabinet, box, or fitting.

How many wires can be pigtailed together?

The only appropriate way to wire a receptacle in a box with three cables is to use pigtails to connect the receptacles. ​Never connect more than one wire under a single screw terminal.