There could be a number of reasons why your furnace’s fan-only mode won’t work. These include: Blown or tripped circuit breaker: The circuit can overload, causing the wires to blow. Incorrect thermostat setting: The wrong temperature prevents the blower motor from starting when it needs to.

What would cause a furnace blower not to kick on?

Make sure that the power cord hasn’t melted or a fuse hasn’t been blown. If your cables are looking fine, try unplugging the fan for a few minutes and then plugging it back in again. Sometimes, this process can reset the motor and solve your furnace problems.

Why will a blower run on the on position and not on auto?





That’s because if the heater never warms up then the fan controller won’t automagically turn on the blower fan. Let me know what you find. Electric split unit trane the fan comes on in the on position but not in automatic. Heat or cool isn’t working on the condenser or evaporator .

Can I run the fan only on thermostat?

You can run your system’s fan independently of heating or cooling. So your system doesn’t need to be actively heating or cooling to run the fan. However, you can only run the fan when your thermostat is set to a temperature mode (like Cool mode, for example).

Is it OK to run the fan only on the heater?

Running your furnace fan all the time isn’t exactly a bad thing. In fact, there’s no need to worry about the fan wearing out or breaking down because it’s designed to run continuously, and there’s an array of benefits connected to this. Here are some of them: Better circulation of heated and cooled air.

Where is the blower motor reset button?

Locate the reset button on the furnace and press it to reset the furnace. It is usually located inside the blower compartment on the side of the blower motor. Be cautious as the housing may be hot. If the button is popped up, press it down.

How do I reset my blower motor?





How to Find and Reset your Furnace Motor Blower

  1. Step 1: Turn off the power to the furnace. …
  2. Step 2: Remove the blower compartment cover. …
  3. Step 3: Make sure the blower is completely cooled off. …
  4. Step 4: Locate the reset button. …
  5. Step 5: Press the button in (assuming that this is your issue and that the button has popped).


How do you bypass a thermostat on a fan?

Quote from the video:
Quote from Youtube video: Ones your jump ring stick this jumper in there and tighten those screws back up and flip the furnace which Bagon. Well guys and that is how you bypass your thermostat.

How do you test a fan limit switch?

Quote from the video:
Quote from Youtube video: So at 100 degrees the furnace will come on and at 200 degrees the gas valve will turn off now to test the function of this limit control we use our electrical tester.

How do you bypass a blower motor relay?



Quote from the video:
Quote from Youtube video: The easy way to do this would be to simply bypass the dead relay on the board and wire the blower motor directly.

Does fan only bring in outside air?

Hot Ducts. It is more energy efficient to run the fan without the air conditioner, but only in certain situations and for short periods of time. The truth is that your ducts are going to heat up when it gets really warm outside, and this is especially true if they are located in your attic or under your floor.

Is it OK to run just the fan without AC?

Running It Without the AC Isn’t Always Efficient



Professional air conditioning repair technicians actually advise against this, however; while it’s true that the fan alone uses less energy than the AC, it will almost certainly result in higher utility bills.

Should the fan be on auto or on?



Keeping your fan on AUTO is the most energy-efficient option. The fan only runs when the system is on and not continuously. There is better dehumidification in your home during the summer months. When your fan is set to AUTO, moisture from cold cooling coils can drip and be drained outside.

How do you jumpstart a blower motor?

Quote from the video:
Quote from Youtube video: And basically this is going to cause it to bypass my thermostat. Here is my thermostat. And you can see it's on the off and auto position.

How can you tell if a blower motor is bad?

Here are 4 common symptoms of a bad blower motor:

  1. Low/no airflow from vents. The classic sign of a bad blower motor is restricted airflow coming from your air vents. …
  2. Strange sounds coming from blower. …
  3. Circuit breaker keeps tripping. …
  4. Hot/burning smell coming from air vents.


Where is the fan limit switch on my furnace?



Your fan limit switch is located inside the furnace panel cover, usually near the upper right corner. The fan limit switch is responsible for turning the blower on and off at the appropriate times.

How do you reset a fan limit switch?

How to Reset a Furnace Limit Switch

  1. Locate your furnace’s heating duct. …
  2. Locate the white limit switch. …
  3. Look at each arm to identify the settings. …
  4. Identify the component (setting) located in between the two arms. …
  5. Set the temperature on the middle component to approximately 105 to 115 degrees Fahrenheit.

How do I know if my fan limit switch is bad?

If the furnace continually runs, yet no heat comes through the system, you may have a problem with the fan limit switch. You may also notice a problem if the blower does not run, or does not stop running when it normally would.

Can you bypass a fan limit switch?

Yes, you can bypass the high limit switch for testing.

How do you fix a limit switch?



Quote from the video:
Quote from Youtube video: Install the new limit switch and secure it into place. Next connect the wires. Now replace the upper. Cover. Next open the gas valve. Now turn on the power to your furnace.

How much does a fan limit switch cost?

$4 to $25

Average Cost of a New Furnace Limit Switch



You will need to buy a high limit switch that is produced by the same manufacturer as your furnace unit. Depending on who your OEM is, this component could roughly cost you anywhere from $4 to $25.