If your pilot light won’t stay alight, it might be the thermocouple. Sometimes dust buildup collects on the thermocouple and blocks the sensor. Try cleaning the thermocouple and then relighting the pilot light. If it continues to go out, the thermocouple might need to be replaced.

Why won’t my boiler pilot light come on?

If the boiler is not igniting, there is a possibility the valve is blocked, seized or there is damage in the wired connections. No Pilot Light: When the boiler is not igniting and the pilot light has gone out, this usually means debris has blocked the jet.

How do I get the pilot light back on my boiler?





How do you relight the pilot light on a boiler?

  1. Turn the gas to ‘pilot. ‘
  2. Press and hold the reset switch for one minute and hold a flame to the pilot light at the same time. …
  3. If all is working as expected, return any casing/doors and turn the gas from ‘pilot’ to ‘on.


How do I manually light the pilot on my boiler?

If you have a manual pilot light on your boiler, follow these instructions:

  1. Turn your boiler’s gas control knob to its “off” setting. …
  2. Turn down the thermostat until it is at the lowest setting.
  3. Remove the boiler’s cover or panel.
  4. Find its pilot light. …
  5. Turn your gas control knob to the “pilot” setting.

Why isn’t my boiler firing up?

Another possibility is that your gas meter is frozen, which leads to low gas pressure. Last but not least, the gas valve, which would normally open to provide more fuel, might be the culprit of your low gas supply issues. If it’s faulty or damaged, the gas cannot enter the chamber, so the boiler won’t ignite.

How do I know if my boiler pilot light is out?





The most obvious sign of the failure of a pilot light will be a lack of hot water or warm air since the burner assembly can’t light and do its job of heating these substances. In many systems, a broken pilot light will prevent the appliance from working at all.

Why has my pilot light gone out?

Some of the possible serious reasons for pilot lights to go out include loose or broken gas valves, thermocouples or heat exchangers, faulty venting, low gas pressure, or high winds. If you believe there is a serious problem, don’t hesitate to contact a professional.

Can I relight the pilot light by myself?

If your pilot light goes out, your furnace will not be able to produce heat because its burners will not ignite. Often, homeowners can relight the pilot themselves.

What happens if your pilot light goes out?

This continuously burning flame will ignite the gas, when the gas valve opens. Then, this heat warms the air brought into your furnace, which will be redistributed throughout your home. If your pilot light is out, you may experience your furnace blowing cold air.

Should a boiler pilot light always be on?



The pilot light must always stay on or gas will easily escape. If the pilot light keeps turning off, then your boiler is not working. Older combi boilers may sometimes have pilot lights that flicker off, but can be restarted easily.

Why is my furnace clicking but not turning on?

You Have a Faulty Ignition Sensor (Pilot Light)



The pilot light or ignition sensor is usually the most common issue when your furnace will not ignite. This is typically the problem if you can hear your furnace click on but it does not fire up.

How do you reset the pilot light on a Worcester boiler?

In most cases, you will simply need to hold the button marked ‘reset’ for three seconds. In some models you may see a reset light at the end of the temperature dial. In this case, just turn the dial down to the reset light, leave it there for three seconds and then turn it back to its original position.

How do you reset the pilot light on a Baxi boiler?



To reset the boiler, turn the temperature control knob fully anticlockwise. Hold until the red lockout light goes out, then turn the control knob back to the desired setting. If your timer is calling for heat, the burner light will come on to indicate the boiler has fired up and is heating your system.

Is it safe to relight a pilot light?

Safety First



You should always proceed with care when relighting a pilot light, since the gas used to power your hot water heater is flammable and potentially dangerous. If at any time you smell gas, you should shut off the gas valve right away, open windows, and avoid turning on any lights.

Should a boiler pilot light always be on?

The pilot light must always stay on or gas will easily escape. If the pilot light keeps turning off, then your boiler is not working. Older combi boilers may sometimes have pilot lights that flicker off, but can be restarted easily.

Why is my Baxi boiler not firing up?

A common culprit for this fault on Baxi boilers is a lack of pressure. If your system is set lower than 1.5 bar then it won’t operate correctly. Now, the quick fix is to top up the boiler pressure using the filling loop. And once you’ve topped up the boiler pressure, you’ll need to reset the boiler.

Why is the heating not coming on?



Dirty and clogged filters are one of the primary causes of furnace problems and can cause high operating costs. The heat exchanger can overheat and shut off quickly when filters are clogged with dust and dirt. This also causes soot buildup on the heat exchanger, which makes your furnace run less efficiently.

How do you reignite a Baxi boiler?

Quote from the video:
Quote from Youtube video: If your boiler has a similar display panel to the one shown here should you ever need to reset the appliance. Simply press the reset button in for no longer than two seconds. If your boiler has a

Where is the fuse in my boiler?

Check your boiler fuse isn’t blown



Most likely, it’ll be next to your boiler – or very near by. If it’s not there, look in your airing cupboard where your hot water tank is (if you have one). It should be in that cupboard somewhere.

What does flame failure mean on a boiler?

A flame failure device or FFD is a safety device used around the world in industrial boilers and burners. It cut off the fuel supply whether gas or fuel oil; thus avoiding hazardous situations. You can consider it as a safe trip that restricts the flow of fuel to the burner in the event flame goes off unexpectedly.