Can I put a main breaker in a sub panel?

The subpanel may be equipped with a main breaker to allow for power interruption without having to go back to the main panel, but it is not required to have a main shutoff circuit breaker, since the feeder breaker back in the main panel serves this function.

Can I run a sub panel off a 30 amp breaker?





Quote from the video:
Quote from Youtube video: So if you needed a 30 you would want to go no less than a 50. Here. We've got a three wire with a ground number 10 set that is feeding our panel for 30 amps.

How far can I run a sub panel from the main panel?

You must provide from 3 to 4 feet of clearance on all sides of the panel depending on the voltage to ground. You may not know this voltage, so it’s best to provide 4 feet. The panel must be easily accessible, so don’t install it too far above the floor; 4.5 to 5 feet is about right.

Can you run 2 sub panels off the main panel?

You can add as many subpanels as you need providing the combined electrical demand is below 160 amps. If all the circuitry was operating at once, the electrical service could become overloaded. However, all combined circuitry would not likely be on at any given time.

Does a subpanel need a main disconnect?

It’s ok for a subpanel to have a main disconnect, but it’s not required. In this case, the disconnect was located outside of the condo unit. On condo buildings, it’s common for all of the main panels to be located in a single room, usually in the basement of the building.

Can you run a 100 amp sub panel off a 100 amp main panel?





Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A.

How many circuits can you have on a 30 amp sub panel?

To summarize the last 8 comments: There is nothing wrong with having 4 15amp circuits in a sub-panel that has a 30 amp main breaker. You can use max 15 amp on any one circuit, and max 30 amp all combined.

How many breakers can you have in a 30 amp sub panel?

The amount of current that is required for the connected loads can only be supported by a 30 Amp sub-panel. The maximum quantity of branch circuits can be determined with a load calculation. Two 15amp breakers or one 15amp and one 20amp can be used on a 30amp circuit.

What breaker should I use for a sub panel?

Based on your question, since you will be having a subpanel, you want the breaker feeding the subpanel to be sized for the subpanel or slightly smaller. So if you purchase and install a 200A subpanel, then the breaker should be 200A. If you use a 125A subpanel, then use a 125A breaker.

Can I run a 200 amp sub panel off 200 amp main?



Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

Can I feed a 200 amp sub panel with a 100 amp breaker?

Yes. There is no real NEC provision that would prohibit this so it’s allowed. The 200 amp CB is simply being used as a disconnect if the feeder is protected by a 100 amp OCPD at it’s origin.

Can I run a 100 amp sub panel off 200 amp main?

Can you add a 100 amp breaker to your main panel? Yes you have 12 slots the double pole breaker will only take 2 slots.

Does a subpanel need to be grounded to the main panel?



Most panels come with a bar joining the two, which is easily removed. Code requires subpanels to have a ground connection that’s independent of the main panel’s.

What is the 6 breaker rule?

The “six breaker throw rule” was a requirement in the National Electrical Code that a service must have have a main disconnect that shuts off all power and it cannot take more than six switch throws to do it, and the main disconnect(s) also must be clearly marked, as in the photo above.

What is the 6 disconnect rule?

The rule is six disconnecting means for each service, not six service disconnecting means per building. If the building has two services, you can have a total of 12 service disconnects (six disconnects per service).

Can you have two main disconnects?

The Six Disconnect Rule: The 2020 NEC revision has major impacts on electrical installations. Sometime between the 1925 and 1933 National Electrical Codes , the maximum number of service disconnects changed from one or two disconnects to a maximum of six.

Does a breaker count as a disconnect?



Disconnecting Means.



This can include a switch, a circuit breaker, a cord and plug connection (sometimes), or a group of the aforementioned devices.

What is the maximum number of switches or circuit breakers allowed to disconnect and isolate the service from all other equipment?

Six Switches

Six Switches or Circuit Breakers in One Enclosure. Since the 1937 edition of the NEC, the service disconnecting means used to isolate a building’s premises wiring from the utility provider’s conductors has been allowed to consist of as few as one, but as many as six switches or sets of circuit breakers.

How many fused circuits are permitted without a main disconnect?

(A) General.



There shall be not more than six sets of disconnects per service grouped in any one location.

Do panels with multiple disconnects always have to be grouped together?



The general rules are that the two to six service disconnects permitted in 230.71 must be grouped in the same location, either in a single enclosure or in separate enclosures located adjacent to each other. Obviously, the larger the service, the wider the grouping distance can become.