Absolutely! Most any fitting is perfectly acceptable and legal, just don’t use any reducers, caps or traps in the venting.

Can I use Wye for vent?

Ans: Wye can be used on the horizontal venting of the shower, tub, or lav. Sometimes, it is required for venting if someone wants to use that as a drain, if in any case.

Can you use a wye vertically?





Connecting a trap to a vertical drain with a wye fitting and a 45-degree elbow seems like a good idea. But it’s not. As water drains down the steep slope at the wye, it can create a siphon effect such that water will be sucked out of the trap. And the empty trap will allow sewer gas to flow into your home.

Does a plumbing vent have to go straight up?

Plumbing vents need to be straight on the vertical. This is necessary to avoid any vapor locks from occurring. When there is a bend in the vent pipe, moisture accumulates and is trapped.

How is vent pipe connected?

A revent pipe, also called an auxiliary vent, attaches to the drain line near the fixture and runs up and over to the main vent. It can attach directly behind the fixture or to the horizontal drain line. If two fixtures are on opposite sides of a wall, they can tie into the stack with a sanitary cross.

Can a wye be used horizontally?

Bookmark this question. Show activity on this post. IPC TABLE 706.3 “fittings for change of direction” says wye is okay for horizontal to horizontal.

What does a sanitary Wye look like?





A sanitary wye is a special fitting having the shape of a lowercase Y. It has three openings that are positioned at a 45-degree angle. With this slight bend, wyes are used in opposite cases of tees. They are used to connect vertical lines to horizontal lines.

Can you put a San tee on its back for a vent?

Sanitary tee can be on its back for dry vent, but the vent has to be a vertical dry vent.

Can you put a 90 in a sewer line?

It’s fine to have a larger-radius (sweep) 90-degree bend at the base of a vertical drainage stack where the wastewater starts to travel horizontally. It’s also a good idea to have a sweep 90-degree fitting where a drain pipe pops out of a wall for a kitchen, vanity or laundry sink.

What is the difference between a sanitary tee and a vent tee?

A sanitary tee is a plumbing fixture that allows liquids to drain while also allowing the plumbing system to vent. The fitting resembles a normal tee fitting; the sanitary tee, however, when viewed from the side will have a definite downward sweep to the center inlet.

Does plumbing vent go before or after trap?



We must always keep the vent connection above the trap weir to prevent siphoning and keep proper pressures on both side of the trap.

What is a plumbing cheater vent?

Quote from the video:
Quote from Youtube video: And basically when air is not needed the flap closes and prevents any sewer gases from escaping into the house and it. Allows you to get a vent into your plumbing system without.

Can a toilet vent be downstream?

Can a toilet vent be downstream? Never. A toilet vent always should be upstream. The purpose of the pipe is to allow sewer gases and water from entering your house.

What happens if toilet is not vented?



Poorly-vented drain lines will not be able to effectively move wastewater and solid waste out of your building. This could lead to problems such as overflowing drains, backed-up toilets, and similar plumbing issues.

Can a toilet and shower share a vent?

So yes the shower can also be vented by the wet vent along with the toilet. There is one major stipulation when wet venting multiple fixtures when a toilet is one of them: the toilet must be the last fixture connected to the wet vent.

How far can a vent be from toilet?

6 feet

Keep in mind your toilet still needs a vent, but your trap arm can be as long as necessary. Now on the other hand, if your plumbing code is the UPC, they’re not as generous… In the UPC, the toilet’s trap to vent distance is limited to 6 feet.

How do you vent a toilet without a vent?



You need to implement one vertical vent pipe to the top of your roof, and it will vent the entire system. That open pipe, connected to the waste, sewer, and pipes, will supply air to the waste pipes.

Is there a ventless toilet?

Ventless toilets are just like regular ones, except there is no vent for the toilet to release the water vapor. Instead, they use a siphon action that pulls the water out of the toilet bowl into an underground waste pipe.

What is the difference between a wet vent and a dry vent?

There are two basic ways to supply air to a drain line: through a dry vent or through a wet vent (if codes allow). A dry vent supplies only air to the drain line, whereas a wet vent functions as both a drain line and a vent.

Can a toilet vent be upstream?

A toilet vent can be upstream. The purpose of the vent pipe is to allow the sewer’s gases to escape from the house’s roof rather than inside the house. A vent also allows oxygen to enter into the sewer pipes, which allows the waste to break down and prevents clogging.

Can a toilet be wet vented?



Wet venting is most common in conjunction with toilets and sinks; the drain for the sink is also the vent for the toilet. It can also be used for a variety of other applications but due to the following rules this is the most convenient and common situation to run into.