Yeah, that’s fine, with the proviso that the backfed breaker needs to be tied down so it can’t rock out like most breakers can. It’s an option to just feed the main breaker or main lugs. I’ve never seen tiedown kits for 1-pole breakers so you may need a 2-pole to use one.Nov 10, 2018

Can I backfeed generator through a sub panel?

The panel is connected to the Mains OR to the Generator, but not to both. This means that the generator cannot backfeed into the mains (and put repairfolk at risk). It cannot be on the subpanel because it must come between the mains and the main panel to work.
Dec 21, 2013

Can you backfeed a panel with circuit breakers?

Even a electric panel with a regular main breaker may be backfed by a breaker below it that is used for connecting a generator to the panel for use during a power outage.
Jul 8, 2019

Does a sub panel need a main?

The subpanel may be equipped with a main breaker to allow for power interruption without having to go back to the main panel, but it is not required to have a main shutoff circuit breaker, since the feeder breaker back in the main panel serves this function.
Mar 24, 2022

Can you run an electrical sub panel off a sub panel?

Answer: Yes. The main electrical service panel is where branch circuits originate.

Can you connect a generator to a sub panel?

Since transfer switches can be expensive, another way to install a generator is to have a sub-panel with main breakers and power from the main power or generator. Main panel breaker and generator breaker in sub-panel would have handles interlocked to prevent both being opened and closed at the same time.

How do you make a backfeed cord?

Quote from the video:
Quote from Youtube video: The supplies and tools that I needed were a 30 amp three prong dryer cord a l14 30p plug and this is a 30 amp plug. So this is the plug that will go into the generator.

What is the 6 breaker rule?

The “six breaker throw rule” was a requirement in the National Electrical Code that a service must have have a main disconnect that shuts off all power and it cannot take more than six switch throws to do it, and the main disconnect(s) also must be clearly marked, as in the photo above.
Feb 3, 2020

Can you wire a subpanel with 3 wires?

Another way to wire a subpanel was with a three-wire feed; two hots and a neutral, with grounds and neutrals connected together at the subpanel. In this case, the grounds and neutrals have to be connected together.
Jul 16, 2019

Can you run a 100 amp sub panel off a 100 amp subpanel?

Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A.
Jan 16, 2018

Is a generator interlock switch legal?

Generator interlock kits are legal throughout the United States. However, there are some important points to consider. Many jurisdictions require that interlock kits be installed to match local building codes.
Oct 7, 2021

How do you hook up a generator to a breaker box without a transfer switch?

How to Connect Generator to House without Transfer Switch

  1. Step 1: Create a Place for the Outlet Utility Box.
  2. Step 2: Drill a Hole for Running Your Generator Cables to the Outlet.
  3. Step 3: Install the Waterproof Box Outside Your Wall.
  4. Step 4: Connect the Wire Into the Outlet.
  5. Step 5: Connect Generator to Outlet and Test it.


Can you plug a generator into a breaker box?

Quote from the video:
Quote from Youtube video: All we have to do is put the generator in place plug it in turn it on and flip the switch. And then the transfer switch.

Is it safe to backfeed your house with a generator?

Generator backfeeding can result in death or injury to yourself or a utility worker, not to mention the destruction of your home. Backfeeding is the tying of a portable generator directly to your home’s electrical panel instead of using a transfer switch. It is dangerous. It is often illegal.

What is better interlock or transfer switch?

Compared to a transfer switch, which is limited to a particular number of circuits, an interlock kit allows you to run power from a generator to any circuit within the electrical panel. While this is good in theory, there’s a risk of overloading the generator if it’s not sized according to the load.
Oct 18, 2019

How do you backfeed a house with a portable generator?

People who backfeed their houses connect the generator to an outlet with a homemade cord fitted with two male plugs. With a Generator Backfeed Cord, sometimes called a suicide cord, electrical power enters the main panel through the outlet’s branch circuit breaker.

How do you backfeed a panel?

Quote from the video:
Quote from Youtube video: It's 20 amps going into a 20 amp plug. Going through a 10 foot 20 amp extension cord. Going into another 20 amp male end going into a 20 amp duplex receptacle that is on a dedicated circuit.

Can I backfeed through the dryer plug?

Backfeeding is a dangerous and possibly illegal way to power your home by connecting your generator to an appliance outlet (like a dryer outlet) and allowing electrical power to flow in reverse. Power moves backward to your electrical panel and is redistributed throughout the house.
Sep 14, 2017