Yes. GFCI receptacles are duplex types (2 receptacles in one device), so a 15 A GFCI can be installed on a 20A circuit with no issue. The only time that a 20A GFCI must be used is where a device with a 20A plug will be connected.

What happens if you put a 15 amp GFCI outlet on a 20 amp circuit?

They are just larger than the 15 amp circuits in very old houses. The GFCI receptacle is rated 20 amps since it may have to interrupt a 20 amp circuit when it trips. As in the case of a kitchen appliance circuit. 15 amp receptacles can be used on 20 amp circuits without a problem.

Is it OK to put a 15 amp outlet on a 20 amp circuit?





The amperage of the outlet must never exceed the amperage of the circuit. According to National Electrical Code, only a 15-amp or 20-amp electrical receptacle can be installed to a 20-amp circuit. A 15-amp receptacle may also be installed on a 15-amp circuit.

What is the difference between a 15 amp and 20 amp outlet?

15 Amp vs 20 Amp Outlet: How To Tell Them Apart



Receptacles with a 20 amp current have a similar design to the 15 amp ones, with a single exception: an additional horizontal slot, which forks from one of the vertical slots (picture on the right). This enables 20 amp plugs to be inserted directly into the outlet.

What appliances require a 20 amp circuit?

Kitchens must have at least two 20 amp outlets. These outlets are used to power high voltage appliances such as toasters, blenders, and microwave ovens. The best way to identify a 20 amp outlet is to find the horizontal slot extending from the vertical slots.

Does a refrigerator need to be on a GFCI?

In a dwelling unit (residential), GFCI protection is only required for kitchen receptacles that serve the countertop surfaces. There’s no requirement to GFCI protect receptacles that serve a refrigerator. Unless the fridge is plugged into a countertop receptacle.

Do I need 15 amp or 20 amp GFCI?





The amp rating of the receptacle and circuit do not depend on whether the receptacle is a GFCI or not: If you have a 15 amp circuit, you must have 15 amp receptacles. If you have a 20 amp circuit, you can either have 20 amp receptacles, or 15 amp receptacles if there is more than one (e.g. a duplex receptacle).

How do I know if I need a 15 amp or 20 amp GFCI?

Quote from the video:
Quote from Youtube video: As well as a 20 amp receptacle. And again it has a t-shaped neutral slash so it can receive a special 20 amp plug in addition to the standard 15 amp plug. However. Your 15 amp plug receptacles.

Should a washing machine be on a GFCI?

GFCI Protection:



210.8(A)(10) – All 125V, 15a and 20a receptacles installed in “Laundry Areas” shall have GFCI protection. The NEC doesn’t require GFCI protection for clothes washing machines specifically, but it does for “Laundry Areas.”

Should a freezer be plugged into a GFCI outlet?

However, GFCI’s are prone to a phenomenon called “phantom tripping,” meaning that they sometimes activate -shutting power off to the circuit – under normal, everyday voltage fluctuations. So freezers and refrigerators should never be plugged into GFCI’s.

Should microwave be on GFCI?



Don’t plug your microwave into a GFCI. Also, we don’t know why it worked fine for years. Also you should probably have it plugged into a 20 amp outlet/circuit.”

Does a dishwasher need a GFCI?

Kitchen dishwashers installed in dwelling units require GFCI protection whether hard wired or cord and plug connected. Code Change Summary: A new subsection was added regarding dwelling unit kitchen dishwashers. Now, outlets that supply dwelling unit kitchen dishwashers must have GFCI protection.

Does a garbage disposal need to be on a GFCI?

The National Electrical Code (NEC) does not require a garbage disposal to have GFCI protection. GFCI protection for this appliance is optional. The vibration caused by the operation of a garbage disposal can cause electrical connections to separate.

Is GFCI required under sink?



210.8(A) requires receptacles serving the kitchen countertop to be GFCI protected. It also requires GFCI protection for receptacles within 6′ of a sink, but only sinks not in a kitchen.

Can two GFCI outlets be on the same circuit?

Yes, you can daisy chain GFCI outlets together, but it’s unnecessary and provides no added safety. There’s nothing that says you can’t install multiple GFCIs on the same circuit. However, there is no additional safety gained by doing so.

How many outlets can 1 GFCI protect?

There’s no limit. A standard GFCI will protect up to 20 amps, drawn from any combination of receptacles, either the built-in one or any number of additional ones connected to its load terminals.