STUDOR AAVs installed in attic area must be located a minimum of six (6”) inches above the ceiling insulation. The use of Tec-Vent® in return air plenums shall be allowed only in engineered drainage systems designed by a design professional and approved by the local authority.

Where should I place my air admittance valve?

AAV location



An AAV should be located within the maximum developed length permitted for the vent. It must be located a minimum of 4” above the horizontal branch drain, 6” above any insulation material and within 15 degrees of vertical.

Can you use an AAV to vent a washing machine?





A washing machine, on the other hand, has its own drain trap connected to the standpipe into which the washing machine drain hose empties. You can use an air admittance valve to vent this trap, but you should choose a high-DFU one that is designed for this application.

How long do air admittance valves last?

Air admittance valves are constructed to last you about 20 to 30 years. Therefore, if you’re replacing the valves quite often, there’s a deeper problem. Usually, these happen because of problems with the valve itself. So if you’re experiencing clogging or a bad odor, you’ve got a faulty valve.

Where does a studor vent go?

STUDOR vents should be installed in the vertical, and upright position. A maximum deviation of 15 degrees is allowed. The vent shall connect to the drain vertically for maintaining an unobstructed opening in the piping to the STUDOR AAVs.

Do I need an AAV vent?

In any dwelling, there must be at least one vent open to the atmosphere outside (per code). An external, passive vent relieves positive pressure in the lines. No building should exclusively use AAVs – significant problems will result.

When should I install AAV?





The AAVs shall be installed after the DWV testing required by Section P2503. 5.1 or P2503. 5.2 has been performed. Individual and branch-type AAVs shall not be located not less than 4 inches (102 mm) above the horizontal branch drain or fixture drain being vented.

Can you put a studor vent in the attic?

The Maxi-Vent is discreet – it can be installed in the attic area, or even below the flood level of the highest connected branch. It may also be installed outside the building when used in conjunction with the aluminium cover and polystyrene cap.

Do AAV vents work?

Because air admittance valves and automatic air vents do not allow air to be pushed out through the vent, they don’t perform all of the functions of a venting system. Air admittance valves (AAVs) work with a sealing mechanism that is lifted to let air into the drain system when there is negative pressure.

Can an AAV be installed in a wall?

Each AAV has to be accessible and have unimpeded airflow, so it can’t be sealed inside a wall.

Can an air admittance valve be installed horizontally?



Manufacturers specify that an air admittance valve be installed within 15º of vertical. So the sideways installation shown above is not acceptable, and it will not function properly in that position.

Can you put a plumbing vent in the wall?

To fulfill the second function, the vent must terminate at least a foot above the roof and, as Fantastic Viewpoint advises, at least 10 feet from open doors or windows on your house or on a neighboring house. You can pass the vent through a wall instead of through the roof, but it must still rise over the roof.

Can I vent plumbing into soffit?

Vent terminals extending through the wall shall terminate at a point not less than 10 feet (3048 mm) from a lot line and not less than 10 feet (3048 mm) above average ground level. Vent terminals shall not terminate under the overhang of a structure with soffit vents.

Can a plumbing vent terminate horizontally?



There is no problem with running your vent pipes horizontally as long as you remember that there should be a minimum clearance of 6 inches above the spill line.

Does a plumbing vent pipe have to go through the roof?

The answer is, no, plumbing vents do not have to go through the roof. While roof stacks are the most common form of plumbing vents, you can run a plumbing vent through an exterior wall. The stipulation is that the plumbing vent has to run higher than the highest window of the house.

Are AAV allowed in Florida?

basically not allowed anywhere in the US, and definitely not in Florida. – – – P3114. 1 General. Vent systems using air admittance valves shall comply with this section.

How far can a toilet be from a vent stack?

According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.