What is a multiwire branch circuit? A multiwire branch circuit is a branch circuit with a shared neutral. This means there are two or more ungrounded (hot) phase or system conductors with a voltage between them and a shared neutral.

Can two circuits share the same ground?

The code requires each branch circuit to have an equipment ground (either a wire, or conduit, or cable tray as in 250.120A), they can be shared when they are in the same raceway. If all the 20A circuits are in one raceway then you just need one ground.

Can two circuits share a breaker?





Yes, it’s fine to combine circuits onto one breaker, at which point they become one circuit.

Can you tie neutrals together from different circuits?

Tying neutrals of different circuits together is effectively paralleling wire, which unless larger than 1/0 is also a violation of 310.4. 300.3 references 310.4, tho 300.3 says all conductors of a circuit must be in the same cable, raceway, etc unless allowed elsewhere.

Can a dedicated circuit share a neutral?

Moderator. A dedicated vs separate circuit is the argument– As I seeit a dedicated circuit should not share a neutral and a separate circuit may share it.

Can receptacles share neutrals?

Yes. GFCI receptacles work fine supplied by a multi-wire circuit. GFCI circuit breakers have a separate terminal for the neutral wire which must be run with the hot wire.

What is a shared neutral circuit?





A multiwire branch circuit is a branch circuit with a shared neutral. This means there are two or more ungrounded (hot) phase or system conductors with a voltage between them and a shared neutral.

How do you fix a shared neutral?

Quote from the video:
Quote from Youtube video: Then locate the shared neutrals in the electrical box and remove the wire connectors that splicing them all together then separate and identify each circuits to neutral conductors.

Can you share a neutral on different phases?

as long as the phase conductors are on different “phases” it’s fine. Recent code requires them to be on a double pole breaker though. I do it as much as possible in houses. It’s easier to pull one three wire for two circuits, than 2 separate two wires.

Does NEC allow shared neutrals?

Sharing neutral or yoke



The NEC does not define multiple circuits. However, relating to 210.7, it appears to mean more than one circuit, on separate phases and each with its own neutral. If the circuits were on the same phase, simultaneous disconnection in the panelboard would not be possible.

Can arc fault breakers share a neutral?



Can the AFCI with shared neutral be used for retrofit installations? Yes, for retrofit installation, GE AFCIs can be substituted for the existing thermal magnetic breakers without the need to sort out existing shared or mixed neutrals.

Can you share a neutral on GFCI breaker?

“The only way to use two GFCI receptacles to provide GFCI protection to more than two total receptacles on a shared-neutral circuit is to stop sharing the neutral after the GFCIs – by using two seperate 12/2’s, or 12/2/2.

What is neutral overloading?

So, if your neutral is sized the same as your conductor (which is should be), and you overload the neutral, then your hot line is overloaded by the same margin.

How do you know if a neutral wire is overloaded?



You need to measure the voltage between the Neutral and ground. If you find that teh coltage is more than 5 Volts then it indicates that the neutral is over loaded.

Does current flow through neutral wire?

When electrical current returns to the power supply substation through a neutral conductor (a power line or wire), it is normal for a small amount of current to also flow through the earth. This will result in a small voltage called neutral-to-earth voltage (NEV).