Nope, does not work because you would need a fourth wire past the GFCI to carry protected neutral along with protected hot. You cannot share unprotected neutral and protected neutral on the same wire.

Can 2 GFCI share the same ground?

The only way to use two GFCI receptacles to provide GFCI protection to more than two total receptacles on a shared-neutral circuit is to stop sharing the neutral after the GFCIs – by using two seperate 12/2’s, or 12/2/2.

What is a 12 3 wire used for?





ROMEX® 12/3 wire is used in buildings for circuits that use higher amperage than the standard 20 amps. Most people are not familiar with this type of wire because it is used to hook up heavy-draw appliances such as water heaters and central air conditioning.

What is the difference between 12 2 wire and 12 3 wire?


Quote from Youtube video: 12 2 or 12 3 wire. This is 12 3 wire and what makes it 12 3 is that you got three wires other than the ground. And 12 2 means you got two wires other than the ground.

Can you run two circuits?

No, code does not require the breakers to be tied together (those circuits should trip independently), and you can have two circuits anywhere you want. You only need to tie the breakers together if it’s a 240V receptacle (or circuit).

Can two 20 amp circuits share a ground?

The code requires each branch circuit to have an equipment ground (either a wire, or conduit, or cable tray as in 250.120A), they can be shared when they are in the same raceway. If all the 20A circuits are in one raceway then you just need one ground.

Can you put 2 GFCI outlets in series?





Yes, you can daisy chain GFCI outlets together, but it’s unnecessary and provides no added safety. There’s nothing that says you can’t install multiple GFCIs on the same circuit. However, there is no additional safety gained by doing so.

How many amps can 12 3 wire carry?

20 amps

12/3 wire is only rated for 20 amps.

How far can you run 12 gauge wire on a 20 amp circuit?

After these distances, the circuit will go over the recommended 3% voltage drop. You can run a 12 gauge wire up to 70 feet on a 15 amp circuit. That number drops to 50 feet if you run 12 gauge wire on a 20 amp circuit.

How many receptacles can be on a 20 amp circuit?



The answer to the question how many outlets on a 20 amp circuit is ten outlets. Always comply with the 80% circuit and breaker load rule, allowing a maximum load of 1.5 amps per receptacle. Remember that your circuit, wire sizes, and outlets must be compatible to avoid overheating and electrical hazards.

Does electrical Code allow two circuits in one box?

The answer is yes you can have 2 separate circuits in the same box (they can have a splice also but not needed in your case). The only concern would be the total box fill. Based on the NEC the wire fill would be calculated at 2.0 for each conductor for 14 gauge wire and 2.25 for 12 gauge wire.

Can two different circuits share a junction box?

Senior Member. Yes, multiple circuits may exist in a junction box.

Can I run 2 circuits in the same conduit?



Feed separate circuits through the same conduit. You can do this, just make sure your conduit is large enough to hold the wires easily. The major downside here is that, while it only requires another conduit run, it also requires you to home run three circuits to your house.

Can I ground two circuits together?

So if your area has adopted NEC 2014, you can connect a grounding conductor to the grounding conductor from another branch circuit, as long as both circuits originate from the same panel.

Can 2 power supplies share a common ground?

If the two power supplies share a common ground, or can be made to, then it is no problem. However, the return wire must be sized for the sum of the 8 V and 12 V currents.

Can you tie grounds together from different circuits?

I usually tie them together but this time I thought it was cleaner to separate them. both circuits are properly grounded at the sub panel. The inspector said that for the past 30 years the code has required that all equipment grounds be tied together regardless of what circuit they originate from.

Can two ground wires touch each other?



The reason that wiring devices have grounding connections that accept only one wire is that otherwise, if two ground wires were connected to the device, then if someone later removed that wiring device and then re-applied power without wire-nutting the grounding conductors, there would be a break in the ground path for

Can ground and common on same bus bar?

If the main service panel happens to be the same place that the grounded (neutral) conductor is bonded to the grounding electrode, then there is no problem mixing grounds and neutrals on the same bus bar (as long as there is an appropriate number of conductors terminated under each lug).

Can you tie neutrals together from different circuits?

Tying neutrals of different circuits together is effectively paralleling wire, which unless larger than 1/0 is also a violation of 310.4. 300.3 references 310.4, tho 300.3 says all conductors of a circuit must be in the same cable, raceway, etc unless allowed elsewhere.

Can 2 circuits share neutral wire?

What is a multiwire branch circuit? A multiwire branch circuit is a branch circuit with a shared neutral. This means there are two or more ungrounded (hot) phase or system conductors with a voltage between them and a shared neutral.

Can you daisy chain neutral wires?



Yes, you can and it will work. Ultimately this is your home, you know the reccemended way is to join them all up at the same point and not jump from switch to switch.