Can a subpanel be grounded to the main panel?

Because the ground and neutral bars are separate, all the grounding conductors have to go the grounding bus and all the neutral conductors to the neutral bus. Beyond that, there’s no difference between wiring from a subpanel and a main panel.

Where do you connect the subwoofer ground?

1-5 of 5 Answers



If this is the case, the grounding wire should be attached to a screw on the mounting plate on the rear of the sub, and the other end attached to a grounding point on the rear of the amp or receiver. If there is no hum, there’s no need to use the ground wire.

Should I bond the neutral to ground subpanel?

Rule #3: In a subpanel, the terminal bar for the equipment ground (commonly known as a ground bus) should be bonded (electrically connected) to the enclosure. The reason for this rule is to provide a path to the service panel and the transformer in case of a ground fault to the subpanel enclosure.

Does a subpanel need to be grounded separately?

An insulated neutral must also be separate from the ground bar at the subpanel and if installed in a separate building must have it’s own ground electrode with a solid #6 copper wire attached from electrode to the ground bar. The main service panel ground bar must be bonded and the subpanel unbonded.

Why do you not ground a subpanel?

So, why do you separate the ground and neutral in a subpanel? Because when we bond them together, it gives your neutral wire (the one carrying electrical currents BACK to the source) multiple pathways. That’s how the chassis of some equipment will become energized.

How do you wire a subpanel to a main panel?

Quote from the video:
Quote from Youtube video: The wire. Into the sub panel from the main panel. So we'll be running our six gauge ground wire. And our feeder wire next this is three gauge like I mentioned earlier anything six gauge or smaller.

Should a SubPanel have a ground rod?

Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building.

Does a SubPanel in the same building need a ground rod?

You must, must, must, in every case run a ground ~ from the main to the subpanel. Doesn’t matter if you’re running it 3 feet, to an outbuilding or up a space elevator. You have to run a ground ~ or you are out of Code.

Do you use a bonding screw on a SubPanel?

Quote from the video:
Quote from Youtube video: But in this case. The bonding screw is that green headed screw right there. So that screw just simply threads through the neutral bus.

How do you ground a main electrical panel?

To add grounding to an existing panel, drive a ground rod into the ground and connect a grounding wire to the main electrical panel. Install new power outlets that have a continuous grounding path back to the grounding rod.

How do you install a ground bar to the main panel?

Quote from the video:
Quote from Youtube video: Line up your three holes on the ground bar. Two of them on the nubs. And one of them right above the hole for the screw. And put this screw into the ground bar.

Why does a SubPanel need 4 wires?

The neutral and ground are not bonded in the subpanel. In this setup if a hot wire coming in contact with the non-current carrying parts of the electrical system, (outlet covers, panel covers etc), the 4th ground conductor will provide a low resistance patch back to the source tripping a breaker.

Where do you bond ground and neutral?

Neutral wires are usually connected at a neutral bus within panelboards or switchboards, and are “bonded” to earth ground at either the electrical service entrance, or at transformers within the system.

Can you put neutral and ground wires together?

No, the neutral and ground should never be wired together. This is wrong, and potentially dangerous. When you plug in something in the outlet, the neutral will be live, as it closes the circuit. If the ground is wired to the neutral, the ground of the applicance will also be live.