What size breaker do I need to run a sub panel?

Based on your question, since you will be having a subpanel, you want the breaker feeding the subpanel to be sized for the subpanel or slightly smaller. So if you purchase and install a 200A subpanel, then the breaker should be 200A. If you use a 125A subpanel, then use a 125A breaker.

Can you run a 100 amp sub panel off a 100 amp main panel?

Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

How do you power a sub panel from the main panel?





Quote from the video:
Quote from Youtube video: Together in the neutral bar because in the main panel the neutrals and grounds are bonded together by a bonding strap.

Why is there no main breaker in a subpanel?

So the inside panel is technically a subpanel and does not have a main breaker. 2) The National Electrical Code (NEC) allows it to take shutting off up to six breakers in the main service panel to turn off all power.

Can you run a 200 amp sub panel off 200 amp main?

Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

How far can a subpanel be from the main panel?

The right feet would be between 4.5 to 5 feet.



The cable running from your main panel to the subpanel depends on the amperage rating. For instance, for a 30A panel, use a 10 AWG, three-wire conductor.

What is the 6 breaker rule?





The “six breaker throw rule” was a requirement in the National Electrical Code that a service must have have a main disconnect that shuts off all power and it cannot take more than six switch throws to do it, and the main disconnect(s) also must be clearly marked, as in the photo above.

Is it possible to not have a main breaker?

In these instances the panel in the home is not the electrical service equipment but is instead called a sub-panel. This type of panel doesn’t “require” a main breaker unless it is in a detached structure. Of course it does no harm to have one and one is often installed for convenience.

Do you need a main circuit breaker?

The main circuit breaker provides a safety measure that is reliable. Without the main circuit breaker, you are relying on each of your branch breakers to handle a much larger load than they are designed for. And, shutting off the power to the whole house comes in handy when you are doing any electrical work.

How big of a sub panel can I install off a 200 amp service?

Even though there is no limit on the number of subpanels that you can add to a circuit, it shouldn’t exceed 160 amps when you’re using a 200 amp main panel. Always follow this guide to install subpanels effectively.

Can I feed a 100 amp sub panel from a 200 amp service?



Of course you can, you can add the 100 amp breaker to your 200 amp as long as it isn’t overloaded, to start adding the subpanel you must first calculate how many yards it will be from the main panel to the subpanel, there is a formula that calculates how much friction will be on the wire at the connecting distance,

Can I feed a 200 amp sub panel with a 100 amp breaker?

Yes. There is no real NEC provision that would prohibit this so it’s allowed. The 200 amp CB is simply being used as a disconnect if the feeder is protected by a 100 amp OCPD at it’s origin.

Can you daisy chain sub panels?

Answer: Yes. The main electrical service panel is where branch circuits originate. A branch circuit consists of the circuit conductors between the final over-current device protecting the circuit and the lights, receptacles and equipment supplied by the branch circuit.

How many circuits can be on a 200 amp panel?



How many circuit breakers in a 200 amp panel? Most 200-amp breaker panels have 40 to 42 slots of single-pole breakers or 20 slots for double pole breakers.

How many receptacles can be on a 20 amp circuit?

The answer to the question how many outlets on a 20 amp circuit is ten outlets. Always comply with the 80% circuit and breaker load rule, allowing a maximum load of 1.5 amps per receptacle. Remember that your circuit, wire sizes, and outlets must be compatible to avoid overheating and electrical hazards.

What happens when you put a 20 amp receptacle on a 15 amp circuit?

First off, connecting a 20 Amp load to a 15 Amp circuit will overload the circuit but shouldn’t cause a fire because the 15 Amp breaker will trip. A 20 amp GFCI doesn’t pose any threat just by being there.

Can I use 14 gauge wire on a 20 amp circuit?

NEC 240.4(D)(3) states that 14 AWG must be protected at 15A. You can not use 14 AWG anywhere on a circuit that has a 20A breaker.