If you install a permanent ladder, the attic is now considered “accessible” and per the code section below the cables have to be protected. However, note that you’re only required to protect the cables running across the faces of rafters or studding, not cables running between the rafters or studding.

How do I protect my attic wires?


Quote from Youtube video: And we put these down some of them we had to layer about twice because we had some offsets with a gas line and other things but typically just shimmed it once or twice all the way around.

How do I protect my Romex wire in the attic?





Protecting the cable is as simple as installing “substantial guard strips”, which can simply be a 1×2 furring strip on each side of the cable. If there’s no permanent stairs or ladder, this protection only has to be provided to cables within 6 ft. of the entrance of the attic.

Can you run electrical wire in attic?

Wiring in the attic is typically a non-metallic cable (NM cable). It is allowed in most areas of the US, but not all. Make sure to double-check with the home builder. However, if it is in an existing home, check with your local professional electrician or home inspection company.

Does wire need to be in conduit in attic?

No, conduit is NOT required in attics. Not unless conduit is required in your area. There are other factors involved in wiring in attic spaces, but your question is a bit too vague to go into that.

Can insulation touch electrical wires?

It is perfectly safe for household insulation to touch wires provided the wires or cables are electrically insulated. There also are techniques to make insulation fit better around wires. However, under no circumstances should thermal insulation make contact with live uninsulated wires and cables.

Is it OK to lay loft insulation over electric cables?





Whenever you read about laying loft insulation all the instructions state that insulation should not be laid over wiring. However, if you contact loft insulation companies, they all say the same thing…they lay over the cables!

Can you run Romex exposed in an attic?

Understanding NEC Regulations with Regards to Romex



Romex is a brand name of non-metal sheathing wire. To give you an overview of what the National Electrical Code (NEC) regulations state, Romex wire shouldn’t be left exposed anywhere in the house, be it the basement, attic, or the home itself.

Should cables be clipped in loft?

Power cables such as sockets and showers should be fixed above the insulation and derated apropriately for the temperature likely to be encountered. The general rule is to clip it if someone may trip over it.

How often do you need to support Romex?

15. Romex Wiring Support, NEC 336-18: Stapled, in a manner that does not damagethe cable, within 12″ of electric boxes; every 4-1/2 ft. intervals, and clamped to box. Cables run through holes in studs, rafters of floor joists are considered supported at those points.

Does wiring need to be in conduit?



There are no wires in conduit and they must be installed, or pulled, through the conduit after installation. Rigid conduit is similar to EMT in appearance, but is much stronger. Rigid conduit is used for very large wires, exterior installations and where structural strength is required.

Where is conduit required?

Conduit typically is used only where circuit wires are exposed (or surface-mounted or buried) and therefore need protection from damage or moisture.

Does Romex need to be in conduit?

one reason you don’t put romex in conduit is because it creates more heat and is not advised in conduit if you have conduit you can run insulated wires instead it’s probably cheaper. when you put romex inside conduit The Romex cannot breathe and retains too much heat.

Does electrical wiring go in front of or behind insulation?



Wiring. It is important that wiring is done before insulation is put into place in new construction. Holes need to be drilled into the frame and wires run throughout the walls. Trying to do this kind of work around insulation would provide needless obstacles for the electricians to work around.

Can you put expanding foam around wires?

You have to consider if using foam is safe if you have anything routed inside the cavity, such as electrical wiring. So, if you were wondering whether expanding foam damages wiring the answer is yes. Expanding spray foam without carefully planning can damage electrical wiring.

Is it OK to put a junction box in the attic?

Yes, junction boxes in attics, suspended ceilings and crawl spaces are legal. Basically, the rule is that ALL wire connections must be accessible. In other words, you can’t cut a hole in a wall or ceiling and bury a junction box by covering it with drywall, paneling, tile, or whatever.

How do you protect exposed Romex?

Code and common sense both dictate that Romex shouldn’t be left exposed but must run through conduits. If you are running it through the basement or attic (or both), the wire must past through studs or be secured on top of joists or trusses.

How do you fish wires in an attic?



Quote from the video:
Quote from Youtube video: So it's a little bit easier to work with I'll just use a little chisel. Just make this hole a little bit bigger and I will pull one of these up attached to a string at the end.

Where do you run wires in an attic?

Quote from the video:
Quote from Youtube video: Into the ceiling space down here into the basement which will probably be the other side of this pop the wire. Out. It's got to run through this joist.

Can you staple Romex to rafters?

It is okay to staple Romex along the floor joists, provided you keep it at a safe distance from the edge. This will help you protect it from screws and nails and any critters that may be crawling along the edges – since that is where insects usually decide to burrow. You can also run Romex THORUGH floor joists.

Are junction boxes allowed in attic?

Yes, junction boxes in attics, suspended ceilings and crawl spaces are legal. Basically, the rule is that ALL wire connections must be accessible. In other words, you can’t cut a hole in a wall or ceiling and bury a junction box by covering it with drywall, paneling, tile, or whatever.

Should cables be clipped in loft?



Power cables such as sockets and showers should be fixed above the insulation and derated apropriately for the temperature likely to be encountered. The general rule is to clip it if someone may trip over it.

Where can Romex not be used?

A good rule of thumb is that romex is permitted except in drop ceilings if the walls and roof are built of wood. Ceiling tiles or concrete would make it unacceptable for residential use. The wiring inside a building is called romex because it was originally installed in open racks called romex boxes.

Can you bury Romex without conduit?

Buried or exposed wiring will need to be listed for its application. Underground feeder wiring can be directly buried without a conduit with a minimum of 24 inches of cover. Any wiring placed inside intermediate metal or rigid metal conduits will require at least six inches of ground cover.

Is it legal to run Romex in conduit?

No, you can not run your Romex wiring in conduits. What you’re looking at in the code book is referring to THHN and other wiring, that while insulated with a single coat is not insulated with a second covering and bound to 2 or 3 other wires.