If you see or hear the fan turn on, your blower motor is not the culprit. If the fan does not start, you have a wiring issue (circuit breaker trips) or motor problem (circuit breaker does not trip). While your thermostat may be at fault, only an HVAC technician can diagnose and remedy the issue correctly.Feb 28, 2020

What would cause a furnace blower not to kick on?

Make sure that the power cord hasn’t melted or a fuse hasn’t been blown. If your cables are looking fine, try unplugging the fan for a few minutes and then plugging it back in again. Sometimes, this process can reset the motor and solve your furnace problems.
May 12, 2021

How do you reset a furnace blower motor?





How to Find and Reset your Furnace Motor Blower

  1. Step 1: Turn off the power to the furnace. …
  2. Step 2: Remove the blower compartment cover. …
  3. Step 3: Make sure the blower is completely cooled off. …
  4. Step 4: Locate the reset button. …
  5. Step 5: Press the button in (assuming that this is your issue and that the button has popped).


Is there a reset button on a furnace blower motor?

Locate the reset button on the furnace and press it to reset the furnace. It is usually located inside the blower compartment on the side of the blower motor. Be cautious as the housing may be hot. If the button is popped up, press it down.
Nov 17, 2020

What would cause the blower motor to stop working?

In most cases, a blower motor resistor fails due to corrosion or overheating. Sometimes, the mechanical resistance to the motor rotation causes an excessive electric current that can overheat and prematurely damage the blower motor resistor.
Aug 1, 2021

How do you know if the furnace blower motor is bad?





If you have an overheating blower motor, there will be clear signs. One would be a burning smell coming from your air vents every time you run the heat. Another sign is if the system shuts down, or if the blower stops while you are running the heat. This means the blower motor is overheating.
Nov 22, 2020

How much does it cost to replace a furnace blower motor?

$400 to $600

On average nationwide, a furnace blower motor replacement costs $400 to $600, including parts and labor. A single-speed blower motor costs around $450 to replace while a variable-speed motor costs $600 or more. You’ll also need to budget labor, about $75 to $125 per hour.

How do I test my furnace blower motor?


Quote from Youtube video: And then you put one probe on there and one to the l2. Common neutral bar right here and you should read 120 volts. If you read 120 volts. And your blower motor is not turning on then.

Where is the blower motor switch on a furnace?



Quote from the video:
Quote from Youtube video: Right behind the electrical gas valve. And it's located in the heat exchanger area.

How much does it cost to replace a fan limit switch?

$4 to $25

You’ll need to get a limit switch from the same company that makes your furnace. This component could cost anywhere from $4 to $25, depending on your original equipment manufacturer. At the lower end of this price range, you might like to buy a universal switch.

What controls the blower motor on the furnace?



A fan limit switch is a component of a furnace system that determines when the furnace blower assembly for hot air turns on and off. Essentially, this means that it determines when the hot air should be blown through your ventilation system.
May 30, 2017

Is there a fuse for blower motor?

To protect the blower motor power circuit, a 20-, 25- or 30-amp fuse is usually located in the fuse panel under the dash. The rating of the fuse will depend on the vehicle application and how much power the blower motor requires at full speed.