Start by turning the furnace off, turn your thermostat to “fan only,” and wait a few minutes. If you see or hear the fan turn on, your blower motor is not the culprit. If the fan does not start, you have a wiring issue (circuit breaker trips) or motor problem (circuit breaker does not trip).

What would cause a furnace not to kick on?

Ensure your furnace filters are clean: Your furnace won’t start up if it does not get enough airflow. A dirty air filter can prevent airflow and prevent your furnace from starting up. Check your pilot light: If you have a gas furnace and gas supply is stopped your pilot light will go out.

How do you reset a furnace blower motor?





How to Find and Reset your Furnace Motor Blower

  1. Step 1: Turn off the power to the furnace. …
  2. Step 2: Remove the blower compartment cover. …
  3. Step 3: Make sure the blower is completely cooled off. …
  4. Step 4: Locate the reset button. …
  5. Step 5: Press the button in (assuming that this is your issue and that the button has popped).

What would cause the blower motor to stop working?

The most common causes for AC fan blower motor not working are blown fuse, bad relay, resistor or control module malfunction and faulty blower motor. However, a bad electrical connector or broken wire, or a defect in the climate control unit can also cause the blower motor to stop working.

How do I know if my furnace motor is bad?

What Are Signs Your Blower Motor Needs to Be Replaced?

  1. Poor or Airflow from Air Vents. This will be the first and most obvious sign your blower motor has a problem. …
  2. No Airflow At All From Vents. …
  3. Skyrocketing Energy Bills. …
  4. Strange Noises When You Turn on the Heat. …
  5. Overheating Blower / Weird Smells.




How do I get my furnace to kick on?

Thermostat. If your furnace is not kicking on, it can be an issue with the thermostat. You should first make sure that the thermostat is switched to the heating function. Next, make sure that the temperature that you have the thermostat set on is lower than the temperature in the home.

Do all furnace blower motors have a reset button?

All furnaces are equipped with a reset button. They are generally red or yellow and are located inside the blower compartment. The reset button is a safety feature that will shut down the furnace when a problem is detected, often a hot or overheating furnace, before it trips the circuit breaker.

How much does it cost to replace a blower motor?

Replacing a blower motor costs $450 on average with a typical range of $250 to $800. With a warranty, you might pay as little as $150 for labor alone. For high-end models, like those with large motors or access issues, you might pay as much as $2,000.

Is it hard to replace a blower motor?



The replacement of the blower motor is common and straightforward, so most shops will perform the repair — many on the same day.

How much does it cost to replace blower motor in HVAC?

A blower motor replacement costs $300 to $900 on average if not under warranty or $200 to $400 for labor when under warranty. Replacing a large or variable-speed HVAC blower motor costs $600 to $1,500. Furnace or AC blower motor prices are $100 to $500 on average for the part alone.

How much does it cost to replace a furnace fan?

Whether you’re looking at a furnace blower or an AC blower, both have the same average cost of $250 to $800. This is because it’s the same part that carries out both functions.

Can a blower motor be repaired?



There are a number of things that can go wrong with your heating system, but if the air stops blowing altogether and the same is true on cold air settings, a blower motor replacement is likely in order. The good news is that it’s a fairly straight forward repair.

Can a furnace blower motor be repaired?

Replacing a Furnace Blower Motor

And all you need to make sure is that you have all the required parts according to the model and you are good to go with replacing the motor all by yourself. The Blower Furnace units are always designed in a way that you can replace the parts individually in case it goes faulty.

How long does a furnace blower motor last?

10 to 20 years



How Long Does a Furnace Blower Motor Last? Blower motors are designed to last just as long as your furnace itself, anywhere from 10 to 20 years.

How do you test a blower motor?

Disconnect car battery. Detach the blower motor from its connector. Unscrew all the screws on the blower motor. Place them in small container.
If the blower motor isn’t running you should:

  1. Use voltmeter or ohmmeter to check for a blown fuse. …
  2. Start car and see if blower motor works.

What causes a furnace blower motor to go bad?

Blower motor breakdown can be the result of anything from old age to failed bearings, high amp draw, electrical failure in the windings, dirt accumulation, and more. “The most common cause is dirt accumulation due to lack of maintenance,” said Tom Beaulieu, president of Bay Area Services Inc.