How do you reset a furnace blower motor?

Locate the reset button on the furnace and press it to reset the furnace. It is usually located inside the blower compartment on the side of the blower motor. Be cautious as the housing may be hot. If the button is popped up, press it down.
Nov 17, 2020

How do you troubleshoot a blower motor on a furnace?

Quote from the video:
Quote from Youtube video: If the blower motor does not come on while it's bypassed like that that means your blower motor is bad and it needs to be replaced. And the way I usually do it in the field.

How do I reset my blower switch?

How to Find and Reset your Furnace Motor Blower

  1. Step 1: Turn off the power to the furnace. …
  2. Step 2: Remove the blower compartment cover. …
  3. Step 3: Make sure the blower is completely cooled off. …
  4. Step 4: Locate the reset button. …
  5. Step 5: Press the button in (assuming that this is your issue and that the button has popped).


What can cause a blower motor to stop working?

In most cases, a blower motor resistor fails due to corrosion or overheating. Sometimes, the mechanical resistance to the motor rotation causes an excessive electric current that can overheat and prematurely damage the blower motor resistor.
Aug 1, 2021

Can you run furnace without blower?

The furnace can produce heat inside the combustion chamber—but that heat won’t go anywhere if the blower fan isn’t running. Because there’s a danger of the furnace overheating without the blower fan, the furnace won’t operate unless the blower has power.
Jan 9, 2017

Do all furnaces have a reset button?

All furnaces are equipped with a reset button. They are generally red or yellow and are located inside the blower compartment. The reset button is a safety feature that will shut down the furnace when a problem is detected, often a hot or overheating furnace, before it trips the circuit breaker.
Nov 17, 2020

How do I know if the blower motor is bad?

Here are 4 common symptoms of a bad blower motor:

  1. Low/no airflow from vents. The classic sign of a bad blower motor is restricted airflow coming from your air vents. …
  2. Strange sounds coming from blower. …
  3. Circuit breaker keeps tripping. …
  4. Hot/burning smell coming from air vents.

Jul 14, 2021

How much does it cost to replace a furnace blower motor?

$400 to $600

On average nationwide, a furnace blower motor replacement costs $400 to $600, including parts and labor. A single-speed blower motor costs around $450 to replace while a variable-speed motor costs $600 or more. You’ll also need to budget labor, about $75 to $125 per hour.

How much does it cost to replace a blower motor?

A blower motor replacement costs $300 to $900 on average if not under warranty or $200 to $400 for labor when under warranty. Replacing a large or variable-speed HVAC blower motor costs $600 to $1,500. Furnace or AC blower motor prices are $100 to $500 on average for the part alone.
Dec 27, 2021

How do I know if I need to replace the blower motor or the resistor?

Typically, if the fan will work on some speeds but not on others, the resistor is suspect. Okay, let’s say there’s no melting going on, but your fan doesn’t work on all speeds. Typically, if the fan will work on some speeds but not on others, the resistor is suspect.
May 13, 2021

Is there a fuse for blower motor?

Many vehicles have two fuses for the blower motor, one in the interior fuse block and the other under the hood. The blower motor is usually under the dashboard on the passenger side.

How do you troubleshoot a blower?

Quote from the video:
Quote from Youtube video: Just turn the blower wheel with your hand and see if it spins freely if there's any resistance or rubbing or grinding that would verify that the blower is in fact seized.

How do I test my furnace blower?

Quote from the video:
Quote from Youtube video: And then you put one probe on there and one to the l2. Common neutral bar right here and you should read 120 volts. If you read 120 volts. And your blower motor is not turning on then.

How long should it take the blower to kick on a furnace?

In normal operation, your furnace blower fan should come on 1.5 to 3 minutes after your thermostat calls for heat and should turn off several minutes after the heating cycle ends.
Oct 25, 2016

How long should it take for furnace blower to start?

In either instance, the blower motor should start within 30 – 90 seconds after burner ignition. If the fan motor does not start, the furnace will overheat and the high-temperature limit switch should cause the burners to shut-off.

Why does it take so long for my furnace to kick on?

Your furnace might not turn on due to a burnt-out pilot light or a dirty flame sensor. A furnace may also be slow-starting because of an issue with its thermostat, so you may need to call in an electrician. Regardless, keep your furnace clean, and don’t forget to schedule an annual check-up before the winter season.
Nov 27, 2021

How do you test a blower motor?

Quote from the video:
Quote from Youtube video: It's two little prongs inside of her. So what you want to do basically is just take one end don't let these two in touch together will be the same sparks as if you was touching.

Where is the blower motor fuse located?

Quote from the video:
Quote from Youtube video: The blower motor fuse is located in a small fuse box just next to the passenger.