What size is the fitting on a gas dryer?

1/2″ IPS pipe is recommended. 3/8″ approved aluminum or copper tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit. If you are using Natural gas, do not use copper tubing. 3/8″ flare x 3/8″ NPT adapter fitting between dryer pipe and 3/8″ approved tubing.

How do you hook up a gas dryer to a gas line?





Quote from the video:
Quote from Youtube video: Remove the red cap from the gas pipe on the rear panel of the dryer. You can connect the flexible gas connector to the dryer gas pipe using a pipe to flare adapter fitting.

Can you connect two gas dryer hoses together?

Can I connect two gas connectors together to obtain the length I need? No, this could influence the gas flow rate, introduce new leak paths, and is expressly prohibited by the model codes.

How long can a dryer gas line be?

Gas ranges and clothes dryers are the only ones that have a flexible connector length of more than 3 feet. Typically, 6 feet is allowed for these appliances.

Is Teflon tape good for gas fittings?

When connecting gas pipelines and their fittings to a stove, grill or other connection, it is important to use Teflon tape designed for gas connections and not Teflon tape designed for water pipes. Teflon tape seals the gas fittings’ threads and keeps leaks from developing.

What size is the gas fitting on a GE dryer?





The gas line connection on the back of GE dryers is a 3/8″ NPT male thread O.D. and is located on the back of the dryer in the lower left-hand corner (approx. 2″ from left side and up 3″ from the bottom of the unit) as you face the back of the unit.

Can I hook up a gas dryer myself?

Not only is self-installation a cheaper option, but it’s also pretty simple to do, even for the non-DIY’ers. While the installation instructions for electric and gas dryers are a little different, both of them can be done with a few tools, a bit of patience and some great directions.

Does a dryer gas line need Teflon tape?

If you ever need to hook up a stove or dryer then you’ll have to work with gas pipe and some fittings. Connecting a fitting to a gas pipe requires some Teflon tape to make a tight seal. Teflon tape comes in a variety of colors based on what you’ll be using it for.

What does a gas dryer plug look like?

Quote from the video:
Quote from Youtube video: This is very different than a standard 120 volt plug it's noticeably larger. And it will have either three or four prongs you have a gas dryer it'll still be plugged into an electric outlet.

What is code for a gas dryer?



Gas-fired clothes dryers shall comply with Section 908.2.

Can a dryer vent touch a gas line?

The following are clearances from the gas regulator vent that should be followed: A building air intake system either gravity or power must be 10 feet away from a gas vent; the clothes dryer must vent at least 3 feet away from the gas vent, and an appliance exhaust and any appliance air intake should be a minimum of 3

Can you reuse a flexible gas line?

Step 2: Do not reuse flexible lines, fittings or valves, even if they are new. Gas line fittings are designed for one-time use only. Disconnecting a previously tightened fitting can damage the connector and make the seal unsafe.

Do you use gas tape on brass fittings?



When threading male threads into mating female threads the use of Teflon tape on brass fittings is highly recommended as long as the fitting does not already have an O-ring or rubber gasket.

Do you use Teflon tape on brass to brass fittings?

Also known generically as PTFE tape, it’s generally used as a sealant and lubricating material, perfect for installing fittings in the kitchen and bathroom. In fact, it’s essential to use thread tape for those household brass fittings unless a rubber seal or gasket is in place.

What do you seal gas fittings with?

Liquid or paste type sealant won’t clog. For gasoline, regular old gasoline resistant Aviation Form-a-gasket Number 3 is the best option. Another product also offered by Permatex is the High Temperature Thread Sealant.

What size is the gas connection on the Samsung dryer?

You need a 3/8″ female NPT x 3/8″ male flare thread adapter. Any good hardware store or plumbing shop.

What size is the gas fitting on a Whirlpool dryer?



1/2 in

The Laundry Gas Pipe Connector is used to hook up your gas dryer. It’s a 4 ft. stainless gas dryer connector. Size is 1/2 in.

What size gas line is needed for a gas range?

Usually the gas line coming into your kitchen will be 1/2-in. black threaded pipe, and the connection to the stove will be either a male (external threads) or female (internal threads) 1/2-in. fitting.

What is code for a gas dryer?

Gas-fired clothes dryers shall comply with Section 908.2.

What do I need to install a new gas dryer?



Your gas dryer will need an appropriate gas hookup. The gas line should have a supply valve in the same room where you intend to install the dryer, preferably within 6 feet (1.8 m) of the unit. If there is no gas pipe in the laundry room, you will have to have one installed by a qualified technician.

Is it safe to have a gas dryer in the garage?

Do not install the dryer where gasoline or other flammables are kept or stored. If the dryer is installed in a garage, it must be a minimum of 18 inches (45.7 cm) above the floor. Failure to do so can result in death, explosion, fire or burns.

Do gas dryers require special venting?

Gas dryers must always be vented.



When gas dryers are running, the combustion that takes place inside produces carbon monoxide, which must be vented either outdoors or into a suitable HVAC ventilation system. Most electric dryers also require venting to keep from blowing hot, moist air into the home.

Can you use flexible duct for a gas dryer vent?

Modern dryer heating elements are very powerful and can ignite the lint accumulated inside the plastic duct and the dryer, starting a house fire. You can use a 4-inch flexible aluminum foil duct that is UL 2158A listed and marked for safe dryer venting.

How do you vent a gas dryer without a vent outside?

Install An Indoor Dryer Lint Trap



Probably the most common way to vent a dryer without a vent to the outside is to use an indoor dryer lint trap. What is this? These lint traps are basically detachable filters that are installed at the end of the flex vent behind the dryer.