Can you cut into a support beam?

Quote from the video:
Quote from Youtube video: But with a notch you can go into the edge as long as the notch is not bigger than one-sixth. The height of that joist.

Can a pipe go through a beam?





The technique of pipe penetrations through the edge beam should be avoided unless there is no alternative. Pipes must pass through the middle third of beams to ensure that the strength of the beam is maintained.

How do you extend a load bearing beam?

Quote from the video:
Quote from Youtube video: But at the same time how much weight is this beam going to be supporting. This beam here is supporting the floor if you're just going to have a beam coming out here and supporting.

Can I drill a 3 hole in a 2×10 floor joist?

Simply following building code, you’ll only be allowed to bore a 3-5/64″ hole through a 2×10 joist. A 2×10 is actually only 9-1/4″ deep, and building codes set the maximum hole size to 1/3 the depth of the member (9-1/4″ / 3 = 3.08333″).

Can plumbing go through floor joists?

Quote from the video:
Quote from Youtube video: Area. For any floor joist whether they're going to be two by six or two by fourteen. And then you are not allowed to drill a maximum distance of more than. One third the width of the joist.

Can I drill a hole in a steel I beam?





With which drill can I drill in steel beams? As mentioned above, you can use high-speed steel (HSS) drills. Typical drilling is with an twist drill, core drill or hole saw, in the tool steels HSS, HSS-Co 5 and tungsten carbide. Hole saws can also be used as they do not drill fully into the workpiece like core drills.

Can you cut holes in joists for plumbing?

You can drill the holes anywhere along the length of the joist (first photo). If you have manufactured I-joists, you can drill holes up to 1-1/2 in. diameter almost anywhere in the web area (the area between the flanges).

Can you notch floor joists for plumbing?

You can cut a notch at the end of the joist to 1/4 of the joist’s depth (maximum). Along the outer third of a joist, you can cut a notch a maximum of 1/6 the joist depth and 1/3 the joist length without compromising its strength.

Can I run waste pipe through joists?

Can a waste pipe go through a joist? Running waste pipes through joists should be avoided where possible, as any drilling of joists (also known as notching joists) may weaken them and compromise the structural integrity.

How do you cut floor joists for plumbing?



Quote from the video:
Quote from Youtube video: This big chunk out of the way you can either use a hand saw or a little jam saw or if you're super careful.

How much can I notch out of a floor joist?

Joist Notching Rules



The maximum depth of a notch at the end of a joist (where it rests on a wall or beam) can’t exceed one-quarter of the joist depth. Maximum notch depth in the outer third of a joist is one-sixth of the joist depth. Limit the length of notches to one-third of the joist depth.

How far from end of joist can you drill?

No holes closer than 2 inches to the top or bottom edge. No holes closer than 2 inches to any other hole or notch. No notches in the middle 1/3 of the joist, but holes are permitted here.