Why does my furnace high limit switch keep tripping?

A high limit switch will keep tripping due to a dirty flame sensor, short cycling, obstructed airflow, or a defective switch. These lead to overheating within the gas furnace that triggers tripping as a safety measure to prevent fires. Clean and replace dirty and worn-out parts to fix the problem.

What causes open high limit on Goodman furnace?

Check the filter because there is a possibility that the filter is clogged which has led to the high open limit of the Furnace. Try to rectify the over heater temperature condition, including dirty evaporator coil, supply that got closed, blocked venting of airflow, and many other common causes.

Why is my Goodman furnace short cycling?





A dirty air filter is the most common cause of short-cycling. If your air filter is clogged with dirt, it won’t allow proper air flow to the heat exchanger. That can cause the furnace to overheat and forces the high limit switch to ride to the rescue by shutting the furnace off.

How do you fix the high limit on a Goodman furnace?

Press and hold the red “Reset” button in the center of the rollout limit switch component. Hold the button for one to two seconds before releasing it.

How do I know if my high limit switch is bad?

One of the most common issues that happens when a high limit switch goes bad is that it fails to signal the blower fan to turn off. If your fan keeps running continuously (and you’ve checked that your thermostat is set to AUTO rather than ON), that could be a sign of a bad high limit switch.

What trips a limit switch on a furnace?

If the air inside your furnace gets too hot, the limit switch trips to prevent overheating. If the furnace high limit switch trips due to overheating, there is likely an airflow issue that is preventing proper air movement through the system. Check your air filter, and replace it if dirty.

What causes high limit opening?





What causes a furnace high limit switch to trip? Airflow issues usually cause a high limit switch to trip out. With less airflow going through your furnace, the heat exchanger excessively heats up and causes the limit switch to trip.

How do I reset my Goodman high efficiency furnace?

How do I reset my Goodman furnace?

  1. Turn off the thermostat. Before heading to reset the furnace, be sure to turn your thermostat to the “Off” position.
  2. Flip the circuit breaker. Go to the circuit breaker and flip the switch that corresponds to the furnace. …
  3. Remove the access panel. …
  4. Press the reset button.


Where is the high limit switch on a Goodman?

The switch is usually located above the heat exchanger of the furnace in the hot-air supply room.

How do you reset a limit switch?



If your limit switches trips repeatedly, it can enter a lockdown mode. That is, it shuts down completely. You can try resetting the furnace limit switch yourself if you have a newer model by turning off the furnace for 30 seconds and then turning it back on.

Can you bypass furnace limit switch?

Yes, you can bypass the high limit switch for testing.

How do you reset the rollout switch on a Goodman furnace?


Quote from Youtube video: If your flame rollout switches trip that means this button will be popped out and if you press on it you press in that will reset it and your furnace will come back on.

What will cause a limit switch to open?



The limit switch shuts off the burner when the temperature exceeds a preset temperature. When the temperature reduces to normal, the burner will come back on. The most common reason for limits to open is a plugged filter or a dirty blower wheel. On the left are some high temperature limits used in furnaces.

Where is the rollout switch located on a Goodman furnace?

The rollout switch is located on the side or top of the burner compartment. Most flame rollout switches look like a little metal circle with two wires coming out of the back. What is this? During normal furnace operation, the flames from the burners will be sucked into the heat exchanger.

What causes rollout switch trips?

Rollout switches trip because flames are burning back where they are not supposed to be. Possible causes include a stopped up vent, a stopped up heat exchanger, low gas pressure, or a cracked heat exchanger. All of these conditions are very serious and have the potential to do great harm.

What is high limit switch?

The high temperature limit switch (also known as a furnace plenum thermostat) is a safety device on a furnace that is designed to cut the gas supply when the burner temperature exceeds the safe operating range. When the temperature drops back within the safe range, it will allow the gas valve to open again.

At what temperature will a flame rollout switch typically open?



A flame rollout switch is essentially a safety switch that turns off the furnace as soon as it detects temperatures higher than the furnace’s temperature rating. The shut-off temperature depends on the furnace model, and it varies from 250F to 350F.