What does 7 flashes on a furnace mean?

7 RED FLASHES: This fault code indicates that the flame could not be established. This no-light condition occurred 3 times (2 retries) during the call for heat before locking out. Low gas pressure, faulty gas valve, faulty hot surface ignitor or burner problem may cause this.

Why does my furnace keep trying to start?





What causes the furnace to start then stop? Common causes of furnace short cycling include: Restricted airflow. Airflow can be limited through the system when an air filter is dirty, is not installed correctly, or a filter that is too restrictive is in place.

Why does my furnace keep turning on every 5 minutes?

Air Vents are Shut



If your heater runs every five minutes, then shuts off, then runs again, then this could be the problem. This has a very easy fix – merely check and see that 75 percent of your heat grates’ dampers (the vents in each space) are open.

Why does my furnace shut off and come right back on?

So, if your furnace keeps turning off and on too quickly, your thermostat might be malfunctioning or broken. There are several things that could be causing your thermostat to not work properly. The wiring could be old and need replacing, it might need new batteries, or it could be the location of your thermostat.

Why is my furnace light blinking 6 times?

When the light is blinking six times rapidly, this means the power volt polarity has gotten switched.

How do I reset my Goodman furnace?





How to reset a Goodman furnace through the thermostat

  1. Step 1: Locate the thermostat. …
  2. Step 2: Turn off the thermostat. …
  3. Step 3: Remove the cover of the thermostat. …
  4. Step 4: Locate the reset button. …
  5. Step 5: Press and hold the reset button. …
  6. Step 6: Release the reset button.


Why is my Goodman furnace short cycling?

Reasons for furnace short cycling are: A bad flame sensor (flame rod) A very dirty furnace filter. Blocked heat grates.

What can cause the blower to come back on for a short time after cycling off?

Check for a dirty air filter and replace if needed.



A clogged filter limits the amount of cool air that passes over the heat exchanger, causing it to overheat and shut off. At the same time, your blower turns on to help cool it down.

How do I stop my furnace from short cycling?



Quote from the video:
Quote from Youtube video: So to fix this issue shut off your thermostat. And open up the furnace. And then replace the batteries on the thermostat.

What does a blinking red light mean on a Goodman furnace?

If your Goodman furnace cannot receive a signal from the thermostat and won’t operate, your furnace LED will give a single red flash, after which it will steadily stay on.

What does 10 flashes mean on a Goodman furnace?

10. Read continuous flashing on the LED to mean your furnace has a reversed polarity of 115 volts. Turn off the power and correct the wiring polarity after reviewing the wiring diagram.

What are the codes on a Goodman furnace?



goodman furnace error codes

  • CODE: Steady on. RESULT: Normal operation. …
  • CODE: OFF. RESULT: Control Failure. …
  • CODE: 1 Flash. RESULT: System lockout (Retries exceeded) …
  • CODE: 2 Flashes. RESULT: Pressure switch stuck closed. …
  • CODE: 3 Flashes. RESULT: Pressure switch stuck open. …
  • CODE: 4 Flashes. …
  • CODE: 5 Flashes. …
  • CODE: 6 Flashes.

How do you troubleshoot a Goodman furnace?

Quote from the video:
Quote from Youtube video: Check to see if the ignitor is faulty by removing it and checking it for cracks or other faults. If you don't see any you can use a multimeter to check for continuity. If it's stopping.

Do all Goodman furnaces have a reset button?

The exact location of the reset button will vary by model on each Goodman furnace. However, you will need to open up the front panel of the furnace to access it. In many furnaces, the switch will be located in the air handlers compartment next to the blower motor (it will typically be a yellow or red button).

What does 8 flashes mean on a Goodman furnace?

igniter relay fault



According to the control manufacturer, the eight (8) Flash Fault Code indicates an igniter relay fault or a shorted HSI. Field indications; however, has linked this fault code to either an open or insufficient grounding of the furnace.

What does 9 flashes mean?

9 (quick or very quick) flashes for West • continual (quick or very quick) flashes for North.