How do you extend a drain pipe from a wall?

Quote from the video:
Quote from Youtube video: The drain pipe coming out of the wall to one and a half inch PVC pipe from the Builder. So what I have here is this is a one and a half inch. This is a flush inside coupling. So this will cement.

How far does a drain have to be from the wall?





Discharge hole (vertical): Drain located at floor height; distance is zero. Fixture (side to side buffer): Measured from center of the toilet to either side, minimum. clearance is 15 inches to any wall or other fixture; 18 inches is recommended if the bathroom layout allows for this.

How far should drain pipe stick out of wall?

Wall Drains



Like the supply stub-outs, the drain stub-out extends from a fitting — usually a sanitary tee — to a point 3 or 4 inches beyond the wall. The drain, which is usually 2-inch plastic pipe, maintains a minimum slope of 1/4 inch per foot from the stub-out to the point where it ties into a main waste pipe.

How do you fix a sink drain offset?

Quote from the video:
Quote from Youtube video: This is an ancient quarter by inch and half trap adapter keep it in the middle of the tailpiece. So you can raise or lower it if needed to gain the correct slope. And dry fit the p-trap on the drain.

How do you lengthen a drain pipe?

Quote from the video:
Quote from Youtube video: So you need the proper washer insert the retention nut. And the nylon washer. And loosen up there p-trap. And install the extension tail piece. And stole another retention nut.

How do you extend PVC pipe from a wall?





Sand the pipe so that the edges are smooth without burrs. Next, apply PVC primer to the outside of both the old and new pipe, as well as the inside of your PVC coupling. Brush PVC cement onto all three areas, and attach the pipes, holding them firmly for five seconds each to permit setting.

How far off wall should soil pipe be?

How far should the toilet waste pipe be from the wall? This is called your ‘toilet rough-in’ distance, meaning the distance from the wall to the centre of the waste pipe. Most toilets have a rough-in of 12 inches, although older homes can have 10 or 14 inches.

How far should a soil pipe be from the wall?

Generally, this distance tends to be around 300mm in a cavity wall, so take this measurement and add an extra 300mm onto this figure – this will allow the WC waste connector to be fitted.

Where do you put rough in tub drain?

The position of the tub drain will vary, depending on the size and design of the tub, and you’ll need to cut an access hole in the floor at the drain end of the tub to allow for positioning and installing the drain line. This hole should be 9 inches wide and extend at least 12 inches from the wall.

What if my sink drain doesn’t line up with existing pipes?



If the tailpiece will not line up with the trap, move the trap into its original position, tighten the collar with the pipe wrench and obtain a flexible tailpiece extension for your drain. The size is typically 1 1/4-inch in the outer diameter of the plastic pipe.

What if new kitchen sink drain doesn’t line up with existing pipes?

In general, if the P-trap doesn’t line up with the drain, you can adjust the length and height of your drainpipes by cutting them or simply slipping them in and out of their fittings.

Can you use flexible pipe for sink drain?

Flexible drain parts can be used to quickly connect offset sink drains. If you have ever been a little short on pipe or had drain trap fittings that were just shy of the necessary length or angle, you’ll appreciate the usefulness of flexible drain parts.

Is Metal P trap better than plastic?



The main advantage of metal drains is that metal is more resistant to heat than plastic is, even ABS plastic. That’s why metal drains are more commonly used for kitchen drains and strainers. That’s not as much of an issue with bathroom drains that don’t deal with such hot water and certainly not in the same amounts.

Are flexible drain pipes any good?

Problems with flexible drain pipe



The zigzag sides are great for slowing down the flow of water and letting the gunk sit and collect. Making matters worse, since they slow down the flow of water, gunk can easily collect further down the pipe, especially if they pipe already isn’t 100% clear.

Are flexible waste pipes good?

Having to use a flexible waste is just poor plumbing design. In MOST cases. I have had to use a couple recently. The first was to get a bathroom basin waste back a very short distance – joints would not have done it and I have kept it near vertical so very little will catch in the folds.

How do you hook up a flexible waste pipe?

Quote from the video:
Quote from Youtube video: We also make them with different connections on the end for either solvent weld or push fit. And you can clearly see that that is for a push fit fitting.

What is accordion pipe used for?



They are intended to be used as a temporary solution. The major problem accordion pipe has is the collection of grime, hair, dirt, and other small items which may fall in the drain. The design of the pipe allows for debris to easily collect in the waste line.

How do you hook up a flexible soil pipe?

Quote from the video:
Quote from Youtube video: Simply push the egg firmly into the source stack and connect the other to the WC. And there you go done.

Can you extend a pan connector?

This 110mm straight pan connector extension piece can be used to extend a toilet waste drain pipe. This can be cut to the required length, while the thick rubber seals provide great sealing properties.

What is a flex connector?

Description. AnvilFlex® Flexible connectors are used to prevent damage to pumps caused by piping stress. AnvilFlex connectors also absorb vibration and noise found in pump installations. AnvilFlex connectors are easily installed and reduce the possibility of pump failure.