How do you connect a fused spur to a socket?

Quote from the video:
Quote from Youtube video: Side in the FCO coming from this socket outlet. And this the fuel spare we connect all the wires. We took it from the load side. And we connect it to the terminals. In this socket.

What is a fused connection unit?





A fused connection unit (or FCU) is an electrical outlet with an integrated fuse used for connecting permanently installed appliances such as fridges, dishwashers, and waste disposal units to a circuit.

How do you connect an appliance to a fused spur?

Quote from the video:
Quote from Youtube video: The like a sight should be in slide on the earth cable. We make this termination make sure there's no copper outside the terminal why this could potentially be a fire hazard.

What outlet is used in electrical appliances?

Domestic electrical outlets supply 120 volts in North America and 220-240 volts in Europe, with most nations having outlets supplying voltages similar to one of those two values.

How do you tell if a socket is a spur?

Quote from the video:
Quote from Youtube video: The line conductor from the other leg of the ring as you can see here. And then we do exactly the same but vice versa. So we connect the neutral from the other leg onto. The line of the first leg.

Can I put a plug on a fused spur?





If the 13 amp fused spur is on the ring circuit and you want to add a socket to the load side of the fused spur yes that is fine as that individual socket will be protected by the 13a fuse in the spur.

What does fused mean on a plug?

“Fuse the plug” means literally to blow a fuse in a plug and hence render a device inoperable. Many plugs (certainly traditionally in the UK) have a fuse which blows and breaks the circuit, rendering the device inoperable.

How do you wire a fused socket?

Quote from the video:
Quote from Youtube video: So let's look at the side first of all labelled supply. This is our final circuit wiring it may be that we've wired our circuits in PVC PVC twin and CPC cables. Sometimes called twin and earth cables.

How does a fused socket work?

A fused spur is an electrical supply accessory that incorporates a fuse. This fuse, with a lower rating than the fuse for a ring man, allows an electrical supply using one feed cable to a socket to be taken off a ring main.

How do I identify an electrical outlet?



You can tell the type of electrical service to any receptacle outlet by the holes for a plug. A standard 110-volt plug has two rectangular holes, the left one slightly larger, with a hole below that has a rounded top.

How do I know what kind of outlet I have?

You’ll usually find 20A circuits and breakers in kitchens, laundry rooms, and garages, which is where most of the power-thirsty appliances are located. If you’re not sure if an outlet or circuit is rated at 20A, a good way to tell is if the outlet has a little notch added into the left-side prong opening.

What are the types of socket outlets?

9 Types of Electrical Outlets You Can Have in the Home

  • 15A, 120 Volt Outlets. These are the most common in older homes and come in two versions: …
  • 20A, 125 Volt Outlets. …
  • 20A, 250 Volt Outlets. …
  • Tamper-Resistant Receptacles. …
  • GFCI Outlets. …
  • AFCI Outlets. …
  • Switched Outlets. …
  • USB Outlets.

How can you tell if two sockets are on the same ring main?



Plug the lamp into another outlet to determine whether or not that outlet is on the same circuit. If the lamp lights with the breaker still off, then the outlet is on a different circuit.

How many sockets can a fused spur have?

How Many Sockets Can Be on a Spur? Only one spur can be connected to a single socket.

Can I spur off a fused spur?

the regs say you can have unlimited fused spurs but only the same number of unfused spurs as there is sockets but you cannot spur of a spur fused or unfused, regards Terry.

Can a fused socket be changed to a plug socket?

1 Answer from a MyBuilder Electrician



Hi. There is no problem removing 13amp fused spurs and replacing with socket outlets. You just need to ensure that those circuits (fuses/mcb’s) are backed up by a 30ma RCD as they will now be used to supply mobile equipment rather than fixed.

How many times can you spur off a ring main?



The rules for spurring off ring circuits are you are allowed ONE unfused spur to a socket (single or double) or ONE fused spur to as many sockets as you wish. You can’t have both on the same point.

What happens if you spur off a spur?

The reason for not running two spurs from the same spur “point” is that it can lead to possible overloads in that one leg of the final can become unbalanced and exceed the max. allowed amps for a bit of 2.5mm if the tap off point is near the cu.

How do I know if I have a ring or radial circuit?

Quote from the video:
Quote from Youtube video: And we will tell you why very shortly. With a radial circuit the cables leave the consumer unit go to the points of use and stop the cables do not return.

How many sockets can you run off another socket?

you can have maximum one double socket as a normal spur but if you are going from socket to FCU fused at 13 amp from there you can add as many sockets as you wish as all the sockets and cable will be protected by the fuse so no chance of overloading the cable the fuse will blow first.