https://youtu.be/ovbnQfvRVJc

How high should a stackable dryer outlet be?

Electrical hookups for washers and dryers should be placed within 6 feet of the unit. While a minimum height for outlets in a home may very, depending on local building codes, for convenience both outlets should be placed between 34 and 36 inches high.

How does a stackable washer and dryer hookup?





How to Hook Up a Stackable Washer & Dryer

  1. Position the washer/dryer appliance in front of its final location. …
  2. Push a flexible exhaust duct end onto the appliance’s exhaust opening from the dryer. …
  3. Place a bucket underneath the hot and cold water faucets that extend from the wall behind the appliance.

Does washing machine receptacle need to be GFCI?

GFCI Protection:



210.8(A)(10) – All 125V, 15a and 20a receptacles installed in “Laundry Areas” shall have GFCI protection. The NEC doesn’t require GFCI protection for clothes washing machines specifically, but it does for “Laundry Areas.”

What section of the code refers to the receptacle required for the laundry equipment?

Section 210.52(F) requires at least one receptacle outlet to be installed for the laundry in a dwelling unit.

How close can an electrical outlet be to a water source?

6 feet





According to the National Electric Code, any receptacle within 6 feet of a water source needs to be protected with a GFCI.

How far apart should a washer and dryer be?

Washers and dryers placed side by side typically require a horizontal space of 60 inches or five feet. Measure the depth of the appliances (most are around 33 inches) and add six inches for hoses and venting. Allow one inch on each side and between appliances to reduce noise from vibrations.

Where should dryer vent be stackable?

Quote from the video:
Quote from Youtube video: Completely the original plan was to put the washer and dryer in this back corner the red lines denote the height of the washing machine and the start of the bottom of the drying machine when stacked.

Do stackable washers have to be stacked?

Standard Front Load – These units are full sized units that are purchased separately and can be installed beside each other. Otherwise, the stacking kit must be purchased separately if they are going to be stacked on top of each other.

Does a stackable washer and dryer need a vent?



Stackable washers and dryers typically still need a vent. While they are compact and save space, most are still designed to vent to the outside. If you live someplace where venting just isn’t possible, like an apartment, don’t give up yet.

What is the minimum requirement for outlet receptacle in a bathroom?

The minimum requirement for outlet receptacles in a bathroom is one GFCI-protected receptacle served by a 20-amp circuit. This is a bare minimum, however, and most bathrooms will have at least two receptacles, and often as many of four or five.

What is the maximum distance from the outside edge of a bathroom basin that a wall receptacle outlet can be located within units?

3 ft



A. In dwelling units, not less than one 15A or 20A, 125V receptacle outlet must be installed within 3 ft from the outside edge of each bathroom basin [210.52(D)].

What is the maximum distance from the outside edge of a bathroom basin that a wall receptacle outlet can be located within dwelling units?

three feet

The discussion continues this month with specific requirements pertaining to bathrooms in dwelling units. While receptacles installed more than three feet (900 millimeters) from the outside edge of each basin are permitted, they cannot be counted as a required receptacle.

What is code for distance between outlets?

There’s a reason for that. The US National Electrical Code, Section 210.52, states that there should be an electrical outlet in every kitchen, bedroom, living room, family room, and any other room that has dedicated living space. They must be positioned at least every twelve feet measured along the floor line.

What is the maximum distance between outlets?



12 feet

Since the maximum distance to a receptacle is 6 feet (1.8 meters), the maximum distance between two receptacles is doubled. Therefore, the maximum distance between receptacles is 12 feet (3.6 meters).