It’s measured on the high side (the nearest point or the shortest dimension). Typical language: Vent pipes shall terminate not less than 6 inches above the roof, measured from the highest point where the vent intersects the roof.

How do you measure a vent pipe?

The diameter of individual vents, branch vents, circuit vents and relief vents shall be at least one-half the required diameter of the drain served. The required size of the drain shall be determined in accordance with Table 710.1(2). Vent pipes shall not be less than 1 1/2 inches (38 mm) in diameter.

Does a plumbing vent pipe have to be vertical?





Vent pipes must be installed so they stay dry. This means that they should emerge from the top of the drainpipe, either straight vertically or at no less than a 45-degree angle from horizontal, so that water cannot back up into them.

What is the minimum height of a vent pipe?

6 in.

The International Plumbing Code (IPC), requires plumbing vent pipes to extend vertically at least 152 mm (6 in.) above a roof, per Section 905.5, “Vent Connections and Grades.” Additionally, vent pipes must be at least 305 mm (12 in.) away from a vertical surface.

How much fall does a vent pipe need?

Combination Vent and Drain Systems





The minimum slope depends on the size of the drainage pipe. If it is 2½ inches or less the minimum slope must be ¼ inch per one foot; 3-6 inch pipe requires 1/8 inch per foot; and if the drainage pipe is 8 inches or larger, the slope may be less – 1/16 inch per foot.

Can a vent pipe be horizontal?

2. Can Vent Pipes be Horizontal? There is no problem with running your vent pipes horizontally as long as you remember that there should be a minimum clearance of 6 inches above the spill line.

Can plumbing vents terminate horizontally?

An open vent terminal from a drainage system shall not be located directly beneath any door, openable window, or other air intake opening of the building or of an adjacent building, and any such vent terminal shall not be within 10 feet (3048 mm) horizontally of such an opening unless it is 3 feet (914 mm) or more …

How many fixtures can a 2-inch vent handle?

There can be 24 fixture units on a 2-inch vent according to national building regulations. This allows for a safe, efficient plumbing setup that delivers consistent results.

Can a drain vent pipe be angled?



Do Plumbing Vent Pipes Need to be Straight? Plumbing vents need to be straight on the vertical. This is necessary to avoid any vapor locks from occurring. When there is a bend in the vent pipe, moisture accumulates and is trapped.

How far can a vent pipe run horizontal?

If you have 1- 1/4-inch pipe, the horizontal distance of the vent ought to not be more than 30 inches. For a 1- 1/2-inc pipe the vent must be 42 inches away at the most while a 2-inch pipeline must have an optimum distance of 5 feet.

Do Horizontal vent pipes need to be sloped?

All vent and branch vent pipes shall be so graded and connected as to drain back to the drainage pipe by gravity. Vent and branch vent pipes shall be free from drops and sags and be sloped and connected as to drain by gravity to the drainage system.

How close should vent be to toilet?



6 feet

According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.

How far can plumbing vent be from fixture?

The only vertical pipe of a combination drain and vent system shall be the connection between the fixture drain and the horizontal combination drain and vent pipe. The maximum vertical distance shall be 8 feet (2438 mm). 912.2.

How high should a vent pipe be above the roof?

Unless a roof is to be used for any purpose other than weather protection, extensions of vent pipes through a roof should be terminated at least 12 inches above the roof. The vent should be extended at least seven feet above the roof if it is to be used for something other than weather protection.

How far can tub drain be from vent?



When builders look only at the table without reading the text, they find that a 2-inch-diameter drain can run a maximum distance of 8 feet to the vent.

Can you reroute a vent pipe?

A plumbing vent pipe helps keep this process going by maintaining the air pressure throughout the pipes. But if you’re remodeling a bathroom, repiping a home, or even moving a wall, you may need to reroute your plumbing vent.

Can plumbing vents be combined?

Vent pipes shall be extended separately or combined, of full required size, not less than 6 inches (152 mm) above the roof or fire wall.

Can you vent sewer into attic?

Yes, it allows moisture and odors into you attic and it needs to be extended at least 12″ above the adjacent roof. If you cap it, the fixture it comes from will not drain properly. If it’s a drain, then add a vent through the roof too.