How do you tell which wire is neutral and which is hot?

Quote from the video:
Quote from Youtube video: If you don't get a voltage reading the wire is neutral. If you get a reading the wire is hot you can also use color coding to identify.

Can neutrals and grounds be on the same bar in a sub-panel?





The answer is never. Grounds and neutrals should only be connected at the last point of disconnect.

How do I find the neutral wire in my panel?

Quote from the video:
Quote from Youtube video: If you open up your electrical box. And you see a white wire in there like we've. Got. Okay see this right here.

Do I need to separate ground and neutral in a sub-panel?

The National Electrical Code (NEC) requirement for separated neutrals and grounding wires in a subpanel and separate neutral and grounding conductors back to the main panel, when both panels are in the same building, dates to the 1999 revision.

What happens if you mix up the hot and neutral wires?

This happens when the hot and neutral wires get flipped around at an outlet, or upstream from an outlet. Reversed polarity creates a potential shock hazard, but it’s usually an easy repair. Any $5 electrical tester will alert you to this condition, assuming you have a properly grounded three-prong outlet.

Which wire is hot when both are same color?





In most modern fixtures the neutral wire will be white and the hot wire is red or black. In some types of fixtures, both wires will be the same color. In this case, the neutral wire is always identified by some means. In some cases, there will be small writing on the wiring case.

Can I tie the neutral and ground together?

No, the neutral and ground should never be wired together. This is wrong, and potentially dangerous. When you plug in something in the outlet, the neutral will be live, as it closes the circuit. If the ground is wired to the neutral, the ground of the applicance will also be live.

Does a 240v sub panel need a neutral?

A 240v only panel has no need for a neutral, I have panels in a industrial facility with no neutral, but for residential my jurisdiction requires a 4 wire feed or 3 with conduit as a ground even for all 240v loads.

Where do you bond ground and neutral?

Neutral wires are usually connected at a neutral bus within panelboards or switchboards, and are “bonded” to earth ground at either the electrical service entrance, or at transformers within the system.

Should a subpanel have a ground rod?



Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building. And yes, a sub panel in the same building as the main does not need a ground rod – only the ground wire.

Why does a subpanel need 4 wires?

The neutral and ground are not bonded in the subpanel. In this setup if a hot wire coming in contact with the non-current carrying parts of the electrical system, (outlet covers, panel covers etc), the 4th ground conductor will provide a low resistance patch back to the source tripping a breaker.

Can you wire a subpanel with 3 wires?

Another way to wire a subpanel was with a three-wire feed; two hots and a neutral, with grounds and neutrals connected together at the subpanel. In this case, the grounds and neutrals have to be connected together.

How many conductors are needed for a subpanel?



A subpanel requires two hot wires connected to a 240-volt double-pole breaker in the main panel. It also needs a neutral wire and a ground wire. The cable used for this run is known as a “three-wire cable with ground.” The two hot wires, called feeder wires, will provide all of the power to the subpanel.

Should neutral and ground be bonded?

A high-resistance reading (typically greater than 200 ohms) indicates that there are no metallic paths between the panel and the transformer, and therefore a neutral-to-ground bond in a grounded system is required.

Do you use a bonding screw on a subpanel?

Quote from the video:
Quote from Youtube video: But in this case. The bonding screw is that green headed screw right there. So that screw just simply threads through the neutral bus.

Why do you not bond a sub panel?

Corrosion can happen because of improper subpanel bonding as well. This is because the excessive electrical currents (coming from the hot, neutral, and ground wires) can accelerate the rate at which metal pipes or buildings start to erode.

Why are ground screws Green?



The grounding screws help to prevent shock. The ground conductor is fastened with ground screws that thread into the box. There is a green dye finish on the screws.

How do you wire a sub panel?

Quote from the video:
Quote from Youtube video: Together in the neutral bar because in the main panel the neutrals and grounds are bonded together by a bonding strap.

What wire do I use for a subpanel?

The cable must have a wire gauge sufficient to the amperage of the subpanel—a 100-amp subpanel requires #4 copper wires or, more commonly, #2 aluminum wires, for example. (Aluminum is often used for feeder cables because the cost is typically much lower than that of copper wires.)

Does a subpanel need to be grounded to the main panel?

Most panels come with a bar joining the two, which is easily removed. Code requires subpanels to have a ground connection that’s independent of the main panel’s.