How far can a sink be away from a vent?

Install the vent between the sink P-trap and the point where the waste line leading from the trap drops to the main sewer. If the waste line has a diameter of 1 1/4 inches, the vent can be no farther than 2 1/2 feet from the trap. If the waste line is 1 1/2 inches, this critical distance is 3 1/2 feet.

Can you move the location of a sink?





Moving the sink is almost always possible. The only problem with moving it is how the sink drain is vented. A drain must have a vent so that the water can move freely. Moving the drain and/or the water is very simple in most cases.

How do you plumb a sink drain with a vent?

Quote from the video:
Quote from Youtube video: And this will be the main sink kitchen cabinets will be right here right but now you can see the drain part of it all right there'll be a trap right here and the water will come this way horizontally.

Where should my vent pipe be for a sink?

Vent pipes must be installed so they stay dry. This means that they should emerge from the top of the drainpipe, either straight vertically or at no less than a 45-degree angle from horizontal, so that water cannot back up into them.

How do you move a plumbing vent pipe?

Quote from the video:
Quote from Youtube video: Well off the side of this you could actually have a vent pipe come up and just raise up a little bit and then go backwards you know go go one way or the other. Until it finds a wall.

Can you vent plumbing horizontally?





Can Vent Pipes be Horizontal? There is no problem with running your vent pipes horizontally as long as you remember that there should be a minimum clearance of 6 inches above the spill line.

How do you reroute a bathroom sink?

How to Move a Bathroom Sink

  1. Step 1: Do your homework. …
  2. Step 2: Turn off water. …
  3. Step 3: Detach your bathroom sink from its position. …
  4. Step 4: Close the fixtures and remove the sink. …
  5. Step 5: Set the plumbing fixtures and the drainage on the new location. …
  6. Step 6: Install the sink in your new location.

How hard is it to reroute plumbing?

Relocating plumbing can be a time consuming and hard work. That’s why you should only do it if you have prepared beforehand and if you have confidence in the professionals you chose to do the job. But take comfort in the fact that once it’s done, you won’t have to think about it for a long time.

Does sink need to be centered with plumbing?

Dishes can easily block a centered drain, causing water and food debris to build up. Centered drains are also not ideal in small kitchens. The central placement of the plumbing below the sink wastes valuable storage space.

Does a plumbing vent have to be straight?



Plumbing vents need to be straight on the vertical. This is necessary to avoid any vapor locks from occurring. When there is a bend in the vent pipe, moisture accumulates and is trapped.

Can you put an elbow in a vent pipe?

Note: You may have vent piping, but you still cannot use the tight 90-degree elbow — sometimes called a “vent elbow” — if the joint is below the water level, which is usually at the level of the sink.

Does a vent pipe have to go through the roof?

It does not have to go through the roof. From the plumbing code (I have the 2003 edition), P3103: It must not be less than 4 feet directly beneath a door, openable window or other air intake of the building or adjacent building.

Can I reroute a plumbing vent?



A plumbing vent pipe helps keep this process going by maintaining the air pressure throughout the pipes. But if you’re remodeling a bathroom, repiping a home, or even moving a wall, you may need to reroute your plumbing vent.

Can I redirect a vent pipe?

You can just put an up-turned wye coupling in the existing vent stack just above the existing connections, run it through the same path you show in your diagram, and tie back in with a 90° elbow (or a couple of 45° elbows), and cap off that 2″ pipe in the wall straight above the connections to the big drain pipe.

How do you reroute a vent stack?

Quote from the video:
Quote from Youtube video: Make a cross right about here to connect to the existing vent line that vents the shower drain. But the problem is this copper water lines right on the way look at this copper line. So.

How far should a vent be from a trap?

P3105. 1 Distance of Trap From Vent

SIZE OF TRAP (inches) SLOPE (inch per foot) DISTANCE FROM TRAP (feet)
11/4 1/4 5
11/2 1/4 6
2 1/4 8
3 1/8 12

Does a kitchen sink drain need to be vented?



Without venting, the negative pressure caused by the flow of draining water can potentially suck water out of the drain trap and allow sewer gases to enter the home. The vents allow air into the drain pipes to help keep the drain flowing properly.

How far can a vent pipe be from a shower drain?

The connection between the fixture drain and the horizontal drain and vent pipe is the only vertical pipe of a combination drain and vent system. 8 feet is the maximum vertical distance.

Can a sink and shower share a vent?

You can put the sink drain into the shower drain. 2. If the vent is less than 5 feet from the other fixture, they can share it.

Does a plumbing vent pipe have to be vertical?

Plumbing vents need to be straight on the vertical. This is necessary to avoid any vapor locks from occurring. When there is a bend in the vent pipe, moisture accumulates and is trapped.

Does a vent pipe have to go through the roof?



It does not have to go through the roof. From the plumbing code (I have the 2003 edition), P3103: It must not be less than 4 feet directly beneath a door, openable window or other air intake of the building or adjacent building.

Can you reroute a vent pipe?

A plumbing vent pipe helps keep this process going by maintaining the air pressure throughout the pipes. But if you’re remodeling a bathroom, repiping a home, or even moving a wall, you may need to reroute your plumbing vent.

Can a vent stack have bends in it?

One should avoid bends and turns in the vents to ensure that there is no possibility of a trap. If it is being placed horizontally, ensure that it is at an angle no more than 45 degrees. Essentially, the vent pipe needs to be dry at all times.