Should my inducer fan runs constantly?

Inducer fan motor won’t stop running



If your inducer fan motor keeps on running all the time, it’s most likely due to a tripped safety such as the high limit switch. It could also be due to a bad control board that is “stuck” in the on position for running the inducer fan.

How do you test an inducer motor?





Quote from the video:
Quote from Youtube video: You turn your button to heat you turn the temperature. Up. If at the control board you have 24 volts off from the W to the c-terminal. This is the next thing that gets called alright.

What causes inducer motor failure?

Most inducer motors failures are simply attributed to the older age of the furnace. In most cases, the internal bearings wear out and since the unit is a sealed unit, there is no way to repair the original motor. Instead the unit is simply replaced with a new one.

Can you lubricate an inducer motor?

Quote from the video:
Quote from Youtube video: You have to oil the dropped inducer motor which is this little motor right here this is the draft inducer. And there's two places where you want to oil it you want to use three.

How do I know if my inducer is bad?

Tapping noises are one of the most common signs of a bad inducer motor. These noises may be the result of dirt or soot collecting around the fan shaft. They might also come from the bearing in the motor clicking together. Vibrating noises are another sign of a bad inducer motor.

When should inducer motor run?





Simply put, an inducer fan should start up when your thermostat calls for heat. It will do this anywhere from 30 seconds to one minute. What is this? It then stays running for as long as your system is heating the house and shuts off when your system cycles off.

Should my inducer motor be hot?

The motor had overheat protection in it to keep it from catching fire. This is a high eff inducer so the heat at 60+ is definitely not from exhaust temperatures. It’s likely just hot running motor. Get the amperage tested against the nameplate for assurance but its likely fine.

How long should an inducer motor last?

Furnace inducer motors can have a life expectancy of 12-15 years. A replacement furnace inducer motor can cost around $800.

What does a bad inducer motor sound like?

A failing inducer motor may create a noise shortly after a heating cycle begins. This could be a tapping noise, or a humming or whirring sound. If the unit will turn on but the blower motor is not turning on, there are a couple of ways to check if the draft inducer motor has gone bad.

How much does it cost to replace a furnace inducer motor?



The average furnace inducer motor cost is around $245, when the part is under warranty and you pay only the labor to have it installed. The replacement cost is $465 when the warranty has expired and you pay for the furnace inducer motor.

What does pressure switch open with inducer on mean?

Clogged air intake or exhaust



If the air intake or exhaust is clogged with debris, the pressure switch can remain in the OPEN position. This is because blockages prevent the inducer fan from creating negative pressure. A furnace pressure switch stuck open is a common problem for many homeowners.

What is an inducer limit switch?

On the “first” call for heat, the high limit has cooled enough that the inducer comes on and the burner lights. When the high limit trips, the indoor fan and inducer continue to run until the limit cools, then lights the burner again. It continues this cycle until the thermostat is satisfied.

What causes the inducer limit to trip?



If the inducer is pulling too much flue gas through the orifice, the gas is not having enough time to cool off by staying in the HX long enough.

How do you reset a limit switch?

How to Reset a Furnace Limit Switch

  1. Locate your furnace’s heating duct. …
  2. Locate the white limit switch. …
  3. Look at each arm to identify the settings. …
  4. Identify the component (setting) located in between the two arms. …
  5. Set the temperature on the middle component to approximately 105 to 115 degrees Fahrenheit.

How do you test a thermal limit switch?

Quote from the video:
Quote from Youtube video: To test the component. You can disconnect the wires. And check the resistance value across the contacts to see if it's open right now this switch is closed. And we read 0.0 ohms of resistance.

How can you tell if a limit switch is bad?

Quote from the video:
Quote from Youtube video: Across the limit if it's not tripped. Which should be reading zero terrific Chris. Now he reads 24 volts that means that's a bad limit.

How do you know if a limit switch is bad?



The most common sign of a malfunctioning limit switch is the continuous operation of your furnace’s blower. Just as the limit switch won’t allow the fan to turn on until the warm air has reached the right temperature, the limit switch also shuts down when the air cools to a certain temperature.