What size main breaker do I need for a 125 amp sub panel?

You can run any wire size you want. It’s OK to supply a 125A panel with less than 125A, as long as the breaker in the main panel protects the wires as follows: 14/3 copper feeder needs a 15A breaker. 12/3 copper requires a 20A breaker.

Can I install electrical panel in garage?

The sub-panel can be grounded at the garage. You will have to install a 6 foot ground bar outside the garage and run a ground wire from the sub-panel box to the ground rod. The ground wire does not have to be in a conduit. Remember, you’re working with electricity, so follow good safety procedures.

How do you wire a 125 amp sub panel?

Quote from the video:
Quote from Youtube video: Here's a sub panel. Again the wire colors the black red white green three three three four. I have three current-carrying conductors for a hot hot neutral.

What size wire do I need to run 100 amp Service 150 feet?

#00 AWG wire

Wire Size For 100 Amp Sub Panel 150 Feet Away



100 amp service 150 feet away from the sub panel requires #00 AWG wire (also known as 2/0 AWG wire). This wire has a median ampacity of 175 amps; more than enough than the required minimum 162.5 ampacity.

How do you size a sub panel for a garage?

The size of a sub panel for a workshop should be a minimum of 60 amps up to 100 amp power feed from your house or main service. This is assuming that you have at least a 200 amp main service. It should be 120/240 volt single phase.

What is the largest sub panel I can install?

The limit is that the breaker in the main panel to supply the subpanel has to be 90 Amp or smaller.



There are, in general, three types of cable:

  • Cable that can be direct buried.
  • Cable that can be run through conduit outdoors but can’t be direct buried. …
  • Cable that can’t be used outdoors.


Is there a 125 amp breaker?

Square D Homeline 125-Amp 2-Pole Main Circuit Breaker in the Circuit Breakers department at Lowes.com.

How many amps can a 125 amp panel handle?

The Panel Rating



The panel is rated to support 125 amperes, when connected to a 120/240 volt 3 wire system. This means that 125 amperes can flow through each of the upper bus bars and each main lug, without anything melting or catching fire.

Is 125 amp service enough?

Most homes require an electrical service of at least 100 amps. This is also the minimum panel amperage required by the National Electrical Code (NEC). A 100-amp service panel will typically provide enough power for a medium-sized home that includes several 240-volt appliances and central air-conditioning.

How do you wire a sub panel in a garage?

Quote from the video:
Quote from Youtube video: Here. Then I connected the garage circuit breaker by attaching the neutral wire to the neutral busbar the ground wire to the ground bus bar and the hot wire to the circuit breaker.

Does a sub panel require a main breaker?

The subpanel may be equipped with a main breaker to allow for power interruption without having to go back to the main panel, but it is not required to have a main shutoff circuit breaker, since the feeder breaker back in the main panel serves this function.

Does a sub panel need a ground rod?

Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building. And yes, a sub panel in the same building as the main does not need a ground rod – only the ground wire.

How do you wire a sub panel in a detached garage?

Quote from the video:
Quote from Youtube video: Started out by removing the drywall above the main house the electrical panel to install the new wire that would lead out to the garage. Luckily.

Does a detached garage need a sub panel?

A 100-amp subpanel in a detached garage may be enough to handle high-draw appliances such as refrigerators. As for basic lighting or low-load electronic devices, a 50- or 60-amp subpanel in a detached garage may suffice.

How much does it cost to add a subpanel to a detached garage?

The average cost of installing a subpanel is between $400 and $1,750, depending on the amperage and number of circuits installed. Typically subpanels have 4 to 20 or more circuits and between 100 and 150 amps.

What does the NEC require for a detached garage?

At least one 120-volt, 20-ampere branch circuit shall be installed to supply receptacle outlets in attached garages and in detached garages with electric power. Code Change Summary: A new code section was added to require a 20 amp circuit for a dwelling unit garage.

How many outlets can be on a 15 amp circuit in a garage?

So, how many outlets exactly can you have on a 15-amp circuit? You can install a maximum of 8 electrical outlets on a single 15-amp circuit. The National Electrical Code, or NEC, limits the continuous load capacity to 80% of the rated total load of a breaker.

Does garage wiring have to be in conduit?

Many garages contain one or more walls made of concrete or already drywalled. Cable installed on these exposed surfaces has to be protected by conduit. We show EMT (electrical metallic tubing; Photo 7), but you can also use rigid PVC conduit.