Can I use a service entrance panel as a sub panel?

Yes, you can do that. You will need to remove the nuetral->ground bonding screw from the subpanel. The new panel should have its neutral to ground bonded (unless that is already done at the power meter).

How far can I run a sub panel from the main panel?





The panel must be easily accessible, so don’t install it too far above the floor; 4.5 to 5 feet is about right. The cable you run from the main panel to the subpanel also depends on the amperage rating. You can use 10 AWG, three-conductor wire for a 30-amp panel, but for a 60-amp one, you need 6 AWG wire.

Is a sub panel required?

You Need a Subpanel in Another Area (Convenience)

For example: Installing a subpanel in the garage or workshop for easy access when the power tools trip a circuit breaker.

Why do you need a sub panel?

An electrician might add a sub panel to take the load off of the main circuit breaker panel. This can prevent overloading the electrical system and tripping circuit breakers or melting fuses. Sub panels are also used to separate the electrical needs of specific areas.

How many sub panels can you have on a 200 amp service?





Even though there is no limit on the number of subpanels that you can add to a circuit, it shouldn’t exceed 160 amps when you’re using a 200 amp main panel. Always follow this guide to install subpanels effectively.

Can you run a 200 amp sub panel off 200 amp main?

Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

Can I run a 100 amp sub panel off 200 amp main?

Of course you can, you can add the 100 amp breaker to your 200 amp as long as it isn’t overloaded, to start adding the subpanel you must first calculate how many yards it will be from the main panel to the subpanel, there is a formula that calculates how much friction will be on the wire at the connecting distance, …

How high should a sub panel be mounted?

All electrical panels must have a minimum of 36 inches of clearance in front of the panel, 30 inches of clearance across the face of the panel, and a minimum of 78 inches above the floor from the top edge of the panel.

Can you run a 100 amp sub panel off a 100 amp main panel?



Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

Does a subpanel need a ground rod?

Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building. And yes, a sub panel in the same building as the main does not need a ground rod – only the ground wire.

Can a sub panel have a main breaker?

The subpanel may be equipped with a main breaker to allow for power interruption without having to go back to the main panel, but it is not required to have a main shutoff circuit breaker, since the feeder breaker back in the main panel serves this function.

Can I use a main breaker box as a subpanel?



There’s no problem with having a main breaker in a subpanel. It’s required if your panel is in a separate building and has more than six breakers, but there’s nothing prohibiting it in any other case.

How much does it cost to install a subpanel?

between $400 and $1,750

The average cost of installing a subpanel is between $400 and $1,750, depending on the amperage and number of circuits installed. Typically subpanels have 4 to 20 or more circuits and between 100 and 150 amps.

What is the difference between a service panel and a sub panel?

The main panel (also called the service entrance panel) is the point where you can disconnect your home from the grid since it connects directly to your power company’s supply. All other panels, aside from the main one, are known as sub-panels.

What size breaker do I need for a sub panel?



Based on your question, since you will be having a subpanel, you want the breaker feeding the subpanel to be sized for the subpanel or slightly smaller. So if you purchase and install a 200A subpanel, then the breaker should be 200A. If you use a 125A subpanel, then use a 125A breaker.

How many breakers can I run off a 60 amp sub panel?

The NEC does not allow installing panels rated below 100-amps as the main electrical panel for the house. Modern 60-amp electrical panels are purpose-built as sub-panels and generally only have 8 to 10 slots available for circuit breakers.

How many receptacles can be on a 20 amp circuit?

The answer to the question how many outlets on a 20 amp circuit is ten outlets. Always comply with the 80% circuit and breaker load rule, allowing a maximum load of 1.5 amps per receptacle. Remember that your circuit, wire sizes, and outlets must be compatible to avoid overheating and electrical hazards.

What wire size do I need to go 100 feet for a 60 amp service to a workshop?

What size wire should I use for a 60 amp subpanel? You can get away with 6 AWG when you have a short run of wire, however, due to voltage drop, if you ever decide you want to go more than 100 feet then a 4 AWG is the size you should choose.

How far can you run 6 gauge wire?



Larry Campbell is an electrical contractor with 36 years of experience in residential and light commercial electrical wiring.
For 240-volt circuits:

14 AWG 100 feet
10 AWG 128 feet
8 AWG 152 feet
6 AWG 188 feet

How far can you run 10 2 wire on a 20 amp breaker?

How Far Can You Run 10 Gauge Wire? You can run a 10 gauge wire up to 85 feet on a 20 amp circuit. If you opt to use this type of wire on a 15 amp circuit, it can run up to 115 feet. After these distances, the circuit will go over the recommended 3% voltage drop.