Can you run electrical wire through soffit?

So, can you run wires through the soffit? Well, yes. It is the best way to ensure the wires are hidden and safe. The soffit allows you to completely hide the cables and minimizes the exposure that compromises the system’s effectiveness.

Can I run Ethernet cable next to electrical?





You can run ethernet cables next to electrical cables if the ethernet cable is shielded, but even then you should keep 8in between them. Non-shielded cables can lose data and bandwidth when run next to power cables. PoE cables run too close to power cables can cause heating and fires.

How do you run wires through a roof?

Quote from the video:
Quote from Youtube video: Because they'll create a cone-shaped hole. Which we've done and it does work but usually if we're gonna do that with a bit like this size we're gonna be drilling a hole to the maximum.

Do electrical wires need to be in conduit UK?

9 Answers from MyBuilder Electricians



All cables should either be contained in steel conduit or protected by 30mA RCD. If these two cannot be met, then the cables should be installed at least 50mm (2″) from the surface.

How do you run wires under soffit?

Quote from the video:
Quote from Youtube video: And then from there we're going to take the cat5e cable and we're going to fish it or pull it back this way through this this cavity with a piece of string. But also you could just sneak the cable.

How do you run power to soffit?





Quote from the video:
Quote from Youtube video: Wire. So this one gfi is gonna control everything down the line in order to get into this soft. Fit what we need to do is start from the edge here. And we gotta bend the edges back take the nails.

Do cables need to be in trunking?

There will be no need for trunking as there are no exposed cables.

Is it OK to plaster over cables?

No problem plastering straight over cables but if you think you might ever want to pull them out put some plastic capping over them first.

Can I run power cables horizontally?

Horizontal runs are absolutely fine, as stated above, if you shift a socket across that has a vertical feed there must be a fitting at the point where the vertical feed drops down to meet the horizontal to mark the end of the vertical, that can be a socket, or a spur, or indeed just a blanking plate.

Do electric cables run up or down?



There are a number of electrical wiring safe zones in which the cables should run: Top of the wall – where the wall meets the ceiling there is a 150mm zone where cables should be run. It is at the top of the wall and runs horizontally around the whole wall.

Can I chase horizontally?

Chase cut-outs should always be vertical or horizontal between start and finish on the wall – never cut a chase at an angle between these two, nor step the channel.

Can you run wires behind skirting board?

In the UK it is not allowed to route cables behind a traditional wooden skirting board. However, if the skirting is purpose made for routing cables within it, then that is allowed. Running cables within it is acceptable. Any purpose made skirting for hiding cables is acceptable made from any material.

How do you hide the cables behind skirting boards?



Cable clips don’t hide cables from view, but pin the cable to the wall to keep them tidy. These are mainly used when the cable is required to run around the outside of a doorway, and the clips pin the cable to the top of the skirting and the exterior edge of the architrave to allow for this.

Is it safe to have electrical sockets in skirting boards?

Answered by Farrah, Electrical Safety Expert



There is no legal requirement to replace sockets if they are positioned on skirting boards in an older property but given that the wiring installation is likely to be old, it is advisable to get a registered electrician to carry out an inspection of the electrics.

Can sockets be mounted on skirting boards?

Hi, no sockets should be left dangling in the air – it’s dangerous. All sockets, unless replacing current fittings, should be 50cm up the wall.

What is the legal height for plug sockets?

Sockets need to be installed at least 450mm up from the floor level of a room. TV points, telephone points, doorbells and light switches should be a max height of 1200mm from the floor.

How far should sockets be from the floor?



450mm to 1200mm

UK Building Regulations state that wall mounted sockets should be positioned so they can easily be reachable in the given room. Whilst there are no specific regulations that need to be followed. As a general rule of thumb sockets should be installed at least 450mm to 1200mm up from the floor level of any room.