It is okay to staple Romex along the floor joists, provided you keep it at a safe distance from the edge.

Where can I staple Romex?

Quote from the video:
Quote from Youtube video: So you need to put the cables down flat on top of each other and staple on top of that.

How do I run Romex in my basement?





Running Romex Wire in Basement



You will have to drill a hole in the floor plate (attic) and roof or wall plate (basement) to run the wire. Make sure it is in the same wall cavity as the outlet you are trying to run the Romex to, since you can’t leave it exposed. To run the wire through this hole, use a coat hanger.

Can you run electrical wire along the floor?

Running electrical wires between the subfloor and the surface layer of flooring is not safe, but you can run them under the subfloor itself. To do this, you will need to make holes in the subfloor, and the best place to do this is through the bottom plates of walls.

Does Romex need to be stapled to studs?

It’s code to staple them during new construction. But it’s also acceptable to leave them loose if you’re fishing wires through an existing finished wall in a remodel. Of course, in both cases they should also be anchored to the box.

How tight should Romex staples be?

Do not hammer in those cable staples too tight. They should be just enough to hold the cable in place, but not so tight as to pinch the cable. It may not look like the staple is damaging the conductors, and the problem may not present itself for a few years after installation, as was the case here.

How many Romex wires can you put under a staple?





Secure only one cable under each fastener, in most cases. Sometimes it is permissible to secure two 2-conductor (plus ground) cables under a single staple, for example, but it is preferable not to double up cables. It is not permissible to secure more than one 3-conductor cable under a single staple.

Can I run wire under joists?

Code says that you may not staple wires to the bottom of a floor joist unless the wire is 6-2, 8-3, or larger. Smaller wires must be run through bored holes or be attached to a running board.

How do you run electrical wire from basement to second floor?

Wrap the Ethernet cable with tape along the hinge’s length. Take the cable down to the lower level and feed it through the hole. Run the cable through the basement walls and secure it. Use cable ties to connect the cable to the system board along the wall.

Can you run wire through joist?

If you’re running parallel to joists, staple the wire to the inside of the joist every couple feet. The wire should be at least an inch away from the bottom edge (basically, if you ever cover it with drywall or some other ceiling, you don’t want people putting nails etc into the cable).

When should you staple Romex?



334.30 Securing and Supporting Nonmetallic-sheathed cable shall be supported and secured by staples, cable ties, straps, hangers, or similar fittings designed and installed so as not to damage the cable, at intervals not exceeding 1.4 m (4 1⁄2 ft) and within 300 mm (12 in.) of every outlet box.

How do you secure wires to studs?

Attaching Cables to Studding



In the codebook, section 334.30 states that flat cables must be stapled on the flat side of the cable, not on the edge. This provides a tight wire connection to the stud and prevents any damage to the wire sheathing.

How far apart do you staple electrical wire?

One of the requirements for permanent wiring, and thus for temporary wiring, was the need for adequate support. Article 336-18 stated that cable must be secured in place at intervals not exceeding 4.5 feet (1.37 m) and within 12 inches (305 mm) from every cabinet, box, or fitting.

Can you zip tie electrical wires together?



Electrical zip ties can be used to keep any sort of electric wires properly bundled and out of the way. Whether you need to keep your computer wires tied, an entire server tied down or any other large items keep neat and tidy, cable zip ties are the easy and economical way to get the job done quickly and easily.

How many wires can be in a joist hole?

The Answer. According to the National Electrical Code, you can have 4 12/2 nonmetallic sheathed cables through a single bored hole that is fire- or draft-stopped using thermal insulation, caulk, or sealing foam, or where proper spacing is not maintained for more that 24 in.

Can you run Romex under joists?

It is okay to staple Romex along the floor joists, provided you keep it at a safe distance from the edge. This will help you protect it from screws and nails and any critters that may be crawling along the edges – since that is where insects usually decide to burrow. You can also run Romex THORUGH floor joists.

Can you staple two Romex wires together?

When stacking multiple Romex wires under one staple, the general rule of thumb is to always wire just one wire per stable, and if you really must, staple no more than two wires side by side. In the field, anything more than two wires at a time is known as a stack.

Can you bundle Romex?



If all of these cables are 14/2 romex serving general lighting/receptacle loads, then you can bundle 3 together at most before you have to derate them.

How do you tie Romex together?

Using electrician’s pliers, twist together the stripped ends of the corresponding wires from each strand of 12/2 Romex, white wire to white and black to black. Twist them until they are tightly joined, and secure each joint with a threaded wire cap/nut. Fold both sets of wires neatly into the junction box.

How many Romex Can you bundle together?

Bundling can be cited when there are 9 or more current carrying conductors that are run together for 24 ins or more.So if the framing members are 2 ft apart and you run the NM from member to member together the ahj is correct.