Can I use a service entrance panel as a sub panel?

Yes, you can do that. You will need to remove the nuetral->ground bonding screw from the subpanel. The new panel should have its neutral to ground bonded (unless that is already done at the power meter).

Can I use a 100 amp panel as a sub panel?





Electricians are well versed in how to make these calculations. If you have older 60-amp or 100-amp main service, it is entirely possible that you will need a service upgrade to 150-amps or 200-amps before you are able to adequately power a new subpanel.

Can sub panel be different brand than main panel?

There is no requirement for the main (service) panel and any subpanels to be the same brand. But it is necessary that a panel be configured correctly as a service panel (neutral and ground bonded) or subpanel (neutral and ground not bonded).

What is the difference between a service panel and a sub panel?

The main panel (also called the service entrance panel) is the point where you can disconnect your home from the grid since it connects directly to your power company’s supply. All other panels, aside from the main one, are known as sub-panels.

Can I run a 100 amp sub panel off 200 amp main?

Can you add a 100 amp breaker to your main panel? Yes you have 12 slots the double pole breaker will only take 2 slots.

Can you run a 100 amp sub panel off a 100 amp main panel?





Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

Can I feed a 100 amp subpanel with a 50 amp breaker?

Just wire it up. There is no problem using a sub panel that can take more current than you will ever feed it. Points to note: The cable to your hot tub will be rated for 50A (not 100A); therefore you must not upgrade the breaker in your main panel to 100A.

Can I run a 200 amp sub panel off 200 amp main?

Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

Can you feed a 100 amp sub panel with a 60 amp breaker?

You can feed a 100 Amp panel with a 60 Amp breaker. Keep in mind that the sub panel needs to be rated above the breaker size.

What makes a panel a sub panel?



A subpanel is a smaller service panel that distributes power to a specific area of the home or other buildings on the property. It is essentially a satellite circuit breaker panel that has its own breakers.

How do you tell if a panel is a subpanel?

A main panel is an installed box where the power from the utility company enters the premises. A subpanel is an installed features that acts as a middle ground for the main panel and other types of circuits that are connected to your property.

Can I add a subpanel to a 200 amp panel?

Even though there is no limit on the number of subpanels that you can add to a circuit, it shouldn’t exceed 160 amps when you’re using a 200 amp main panel. Always follow this guide to install subpanels effectively.

How do I run a subpanel from the main panel?



Quote from the video:
Quote from Youtube video: You're going to be adding a subpanel always add the largest panel that that is practical to a door if you were thinking that you needed six circuits.

How many sub panels can you have on a 200 amp service?

200 AMP Service – Feeding 3 Sub-Panels – Wire Size and Set Up Help Needed.

Can you wire a subpanel with 3 wires?

Another way to wire a subpanel was with a three-wire feed; two hots and a neutral, with grounds and neutrals connected together at the subpanel. In this case, the grounds and neutrals have to be connected together.

Does a subpanel need a ground rod?

Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building.

Should a sub panel be bonded?



Rule #3: In a subpanel, the terminal bar for the equipment ground (commonly known as a ground bus) should be bonded (electrically connected) to the enclosure. The reason for this rule is to provide a path to the service panel and the transformer in case of a ground fault to the subpanel enclosure.

Can ground and neutral be on same bar in subpanel?

The answer is never. Grounds and neutrals should only be connected at the last point of disconnect. This would be at main panels only.

Why do you separate the ground and neutral in a sub-panel?

With ground and neutral bonded, current can travel on both ground and neutral back to the main panel. If the load becomes unbalanced and ground and neutral are bonded, the current will flow through anything bonded to the sub-panel (enclosure, ground wire, piping, etc.) and back to the main panel. Obvious shock hazard!

Does a subpanel need a separate ground?

The biggest difference between a subpanel and a main panel is that the ground and neutral buses on a subpanel have to be separated. Most panels come with a bar joining the two, which is easily removed. Code requires subpanels to have a ground connection that’s independent of the main panel’s.