As long as the neutral stays connected for both circuits, all is fine.

Can 2 circuits share a junction box?

The answer is yes you can have 2 separate circuits in the same box (they can have a splice also but not needed in your case).

How many circuits can you have in a junction box?





For example, the smallest 2-by-4-by-1-1/2-inch-deep box can comfortably splice only two cables (four or five conducting wires), while the largest 4-by-4-by-2-1/8-inch-deep boxes can handle as many as four to six cables (up to 18 individual conducting wires).

Can one outlet have two circuits?

It’s possible to safely have two circuits feeding one receptacle, if you have a hot/neutral pair for each segment. Additionally, current code requires dipole breakers in this case, so overload on either circuit shuts off both.

Can you have too many wires in a junction box?

If the box you’re using doesn’t include clamps, buy clamps separately and install them when you add the cable to the box. Mistake: Box too small | Too many wires stuffed into a box can cause dangerous overheating, short-circuiting and fire. The National Electrical Code specifies minimum box sizes to reduce this risk.

Can one switch control 2 circuits?

Double pole light switches, also known as a four-way switch, are two single pole switches put together. Two separate circuits are controlled by one switch. This is typically used to control a circuit from multiple locations in a series of three switches on one circuit.

Can I run 2 circuits in the same conduit?





Feed separate circuits through the same conduit. You can do this, just make sure your conduit is large enough to hold the wires easily. The major downside here is that, while it only requires another conduit run, it also requires you to home run three circuits to your house.

How many Spurs can you run from a junction box?

Each socket outlet or junction box on the ring can only have one spur connected.

What is code for electrical junction box?

Securing Cables



Article 334.30 states that cables coming out of the junction boxes should be secured within 12 inches of the box in all boxes equipped with cable clamps. These cable clamps are not to be removed. 314.17(C) states that cables must be secured to the receptacle box.

How many wires can you run off one outlet?

Never connect more than one wire under a single screw terminal. It’s also not a good idea to direct-wire all three cables to the receptacle by utilizing both the screw terminals and the push-in terminals on the back of the device.

How do you fix an overcrowded electrical box?



Adding an electrical receptacle or switch to an existing box can make it too crowded, but you can remove the old box and add a larger remodeling box without destroying the wall.

Can you extend electrical wire without junction box?

Short answer: NO. Long answer: All splices must be in a junction box, and the junction box must be accessible.

How do you connect 4 wires to a junction box?

Connect the ground wire of the 3-wire cable to the ground wire of the 4-wire cable. Connect the black wire of the 3-wire circuit to either the red or the black wire of the 4-wire circuit. The red and black wires are the”hot” wires. Either wire can be used to power a circuit.

How do you switch between two circuits?



Quote from the video:
Quote from Youtube video: And unused and therefore I will also be changing the light switch to a to a large switch if you're wondering why the light switches are horizontal instead of vertical. It's.

How many can lights on one circuit?

Amount of Lights You Can Put on a 20-Amp Circuit Breaker



A standard 50-watt light consumes less than a half amperage on a 120-Volt circuit. With that fact, a 50-watt light on a 20-amp breaker can have a total of 38 lights on a circuit.

When we require two separate circuits on and off simultaneously with single switch then electric switch is used?

Double Pole Single Throw Switch (DPST)



In OFF position both switches are at open state. This type of switches is used for controlling two different circuits at a time.

Can a broken light switch cause a fire?

Usually, a broken or failing light switch isn’t a fire hazard itself, but it can overheat if the contacts or the switch wear down. Sometimes a bad light switch can cause other components on the circuit, such as a bulb, to become a fire hazard by causing an intermittent current.

Why switch should not be connected to neutral wire?



Solution. In case of excessive current, it is dangerous to connect the switch in the neutral wire. Even if the fuse blows off due to excessive current and the current in the circuit would no longer be conducted, the appliance will still remain connected to the live wire of a very high potential.

Which is better toggle or rocker switch?

Functionality. All in all, rockers and toggles do the same job: turn power on and off. The biggest difference in terms of functionality is that toggles have a bit more “snap” and rockers seem to require a little more force to switch.

Why would you use a rocker switch?

Rocker switches are used in surge protector s, display monitors, computer power supplies, and many other devices and applications. A rocker switch with independent circuitry can have a light activated on the face of the switch in both the on and off positions, which allows the switch to be found easily in the dark.

Why are rocker light switches better?

It has a sleek design that makes it easy to fit into your home décor and rockers are less bulky than toggle switches which work well in tight spaces, but might not be as aesthetically pleasing. The rocker switch also works better with dimmer lights since they can slide up or down easier than toggles!