Should AC condenser be elevated?

If the condenser is not level, then the air conditioner will have trouble working correctly. The pump inside the unit may not work the way it’s supposed to. The condenser pump contains some oil in the refrigerant that moves within the system, then returns to the pump.

Should AC unit sit on the ground?

Can an AC unit sit on the ground? This is generally not advisable. When your air conditioner is resting directly on the ground, critters can make their way inside and cause all kinds of damage. You’ll also find that backyard chores such as mowing the grass become a lot more difficult.

Do AC units need to be elevated?

Over time, this can lead to a shortage of oil in the compressor, causing damage and overheating. Additionally, oil coating the inside of the coils can make it harder for heat to transfer, decreasing the system’s efficiency. Failing to level the outside unit doesn’t just cause problems with oil.

What do I put under my outside AC unit?

You Need a Concrete Slab Under Your Outdoor AC Unit Because:

  1. It keeps your air conditioner from sinking: For an air conditioning system to function at peak efficiency, it is essential that it has room to breathe. …
  2. It keeps oil from spreading: The compressor in your AC unit runs on oil.

What does a condenser sit on?

An AC condenser pad is a platform that provides a flat, stable surface for the outdoor condenser unit. It also helps attenuate the noise that comes from the unit when it’s in operation.

Can you put AC condenser on deck?

Putting it under the deck could cause some problems. I would advise against it. The more airflow through the unit the more efficient it can be. It’s gotta be able to breathe.

How do you build a platform for an AC unit?

Quote from the video:
Quote from Youtube video: So when I set the pad on it it'll be nice and flush along the edge all the way. Around. Okay just like that tall. Done put all the braces on it. All the deck boards. Even put our pads.

Can AC unit sit on pavers?

Quote from the video:
Quote from Youtube video: And enter your air conditioning unit which we do not want to do so by having the air conditioner pulled out before we come in we could do our paving stones.

How do you secure an AC condenser?

Quote from the video:
Quote from Youtube video: Box where the electrical is that will keep the thief from being able to turn off the electrical. That way they can't cut it with bolt cutters.

How high off the ground should a condenser be?

Placing the unit at a decent height (at least 7 feet off the ground) allows for good airflow and convenient drainage.

Does an AC condenser need a pad?

Do I Need an Air Conditioner Condenser Pad? If you have an air conditioner, you absolutely need an air conditioner condenser pad. An air conditioner condenser pad is a thick pad designed to provide a flat, stable surface for the unit to be installed on.

Where should a condenser unit be placed?

The condenser should always go outside of your home and not in an attic, basement, garage, or crawl space.



The top reasons include:

  1. Air supply. The condenser needs an adequate air supply to cool the refrigerant and do its job. …
  2. Airflow. …
  3. Heat.


How far can the condensing unit be from house?

In general, you want the line sets or the refrigerant lines to be less than 50 feet away from a house. Doing this will allow your air conditioning system to have the best performance.

How much space do you need around AC condenser?

The general rule of thumb is to have at least one foot (or 12 inches) of clearance on each side of your air conditioner. Your air conditioner’s manufacturer may have specific clearance recommendations, but they’ll generally recommend between 12 and 24 inches.

How far can condenser be from air handler?

So, you should be good. However, you can’t have a single line set more than 75 feet between each air handler and the condenser. If you need more than that, you’re going to have to do something else or move your condenser.

How far does condenser have to be from wall?

A 30-inch minimum distance between the condenser and the wall must be maintained for effective cooling of the unit.

How far can a C unit be from furnace?

Most manufacturers consider “long line sets” to be be in excess of 50′. As long as the guidelines are followed units can work well with 100′ of line set. An issue can arise if there is an appreciable difference in height between the indoor and outdoor units. By appreciable, I mean over 20′.