Can you run 2 sub panels off the main panel?

You can add as many subpanels as you need providing the combined electrical demand is below 160 amps. If all the circuitry was operating at once, the electrical service could become overloaded.

Can you feed a subpanel with a smaller breaker?





This must be fed by a 125A or smaller breaker in the main panel. Panel rating is the limiting factor. If the main panel’s MAIN breaker is of a size that will adequately protect the feeder wires and the subpanel, then no breaker is needed. Remember: subpanels NEVER need main breakers.

Can a 100 amp panel feed another 100 amp panel?

@tracyrobert Even if you put a double pole 60 ampere breaker in the main panel to protect the new panel feeder, you can still install a 100 ampere panel as the second panel. As Retired Master Electrician points out, the panel rating is the maximum the panel can be used for, not what it has to be used for.

How far can a sub panel be from the main?

You may not know this voltage, so it’s best to provide 4 feet. The panel must be easily accessible, so don’t install it too far above the floor; 4.5 to 5 feet is about right. The cable you run from the main panel to the subpanel also depends on the amperage rating.

Can you feed a 100 amp sub panel with a 60 amp breaker?

You can feed a 100 Amp panel with a 60 Amp breaker. Keep in mind that the sub panel needs to be rated above the breaker size.

Can you feed a 100 amp sub panel with a 50 amp breaker?





Just wire it up. There is no problem using a sub panel that can take more current than you will ever feed it. Points to note: The cable to your hot tub will be rated for 50A (not 100A); therefore you must not upgrade the breaker in your main panel to 100A.

How do you feed a subpanel from the main panel?

Quote from the video:
Quote from Youtube video: Goes into the panel. And on to the ground burn. Everything is connected ready to heat this up at the main panel we've completed the other panel. We've completed this panel.

How do I add a second electrical panel?

Quote from the video:
Quote from Youtube video: So what we're going to do is pull power off of the existing box connect the power here and here with our ground or Commons over here we're going to have to remove two breakers from the existing.

Can I run a 100 amp sub panel off 200 amp main?

Of course you can, you can add the 100 amp breaker to your 200 amp as long as it isn’t overloaded, to start adding the subpanel you must first calculate how many yards it will be from the main panel to the subpanel, there is a formula that calculates how much friction will be on the wire at the connecting distance, …

Can you daisy chain sub panels?



Answer: Yes. The main electrical service panel is where branch circuits originate.

Should a sub panel have a ground rod?

Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building. And yes, a sub panel in the same building as the main does not need a ground rod – only the ground wire.

How do you feed a 200 amp sub panel?

Quote from the video:
Quote from Youtube video: And then you set the top you see a bare copper wire you'll take this bare aluminum wire. And you will put it on that lug also we'll probably add a new lug.

Can you feed a 200A panel with a 200A panel?



Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

How do you size a subpanel?

Subpanel Coverage Area



Measure the length and width of each room and multiply them together to find the square footage of the room. Add up the square footage of all of the rooms to find the total square footage. Multiply the total square footage by 3 (watts) to complete the calculation.

What size wire do I need to feed a 200 amp panel?

What Size Ground Wire for 200 Amp Service. The NEC is the electric code used in the United States. The minimum size for a grounding wire for 200 amp is #4 AWG copper or #2 AWG aluminum, according to Article 250 of the 2020 NEC.

Can I put a 50 amp breaker in a 200 amp panel?

In general, a 200-amp panel should handle no more than 160 amps at once. It’s important to note that people can have 300 or even 400 amps worth of breakers in a 200A panel, as they don’t use all circuits at the same time. Calculating how many circuit breakers you need is also dependent on your home electrical loads.

What size wire do I use for 150 amp service?



Looking at your 150 ampere service as an example (Excluding any temperature or other adjustments). Table 310.15(B)(16) says that 1 AWG copper is good for 130 amperes at 75C. So if no adjustments were needed, 1 AWG would be allowed as service conductors for a 120/240 volts, 3-Wire, single-phase dwelling service.