How far off the ground does a subpanel need to be?

All electrical panels must have a minimum of 36 inches of clearance in front of the panel, 30 inches of clearance across the face of the panel, and a minimum of 78 inches above the floor from the top edge of the panel.

How do you mount a panel on a concrete wall?





How to Attach Paneling to a Concrete Wall

  1. Glue wood strips to the walls at the top, bottom and in the corners. …
  2. Snap chalk lines from the top strips to the bottom strips every 16 inches. …
  3. Cut foam board insulation to fit between the wood strips. …
  4. Cut a piece of paneling to fit the height of the wall minus 1/2 inch.

Where to install sub panel?

Place a subpanel near the main panel to add additional circuits. If you need more circuits to power your electrical devices, install a subpanel adjacent to your main circuit breaker.

How to mount subpanel?

Mount Subpanel

Mount the subpanel about a foot away from the main service panel. Determine how far the wires will have to travel in the subpanel and pull wires (shown) or add cable and strip sheathing accordingly. Remove a knockout slug, slide the wires through, and clamp the cable.

How high should a breaker panel be mounted?





The minimum height for a circuit breaker box is 4 feet, though the ideal height is between 5 feet and 6 feet. The maximum height allowed for the circuit breaker box is 6 feet.

What wire do I use for a 100 amp sub panel?

#4 copper wires

The cable must have a wire gauge sufficient to the amperage of the subpanel—a 100-amp subpanel requires #4 copper wires or, more commonly, #2 aluminum wires, for example. (Aluminum is often used for feeder cables because the cost is typically much lower than that of copper wires.)

Does a sub panel need a ground rod?

Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building. And yes, a sub panel in the same building as the main does not need a ground rod – only the ground wire.

Does a subpanel need to be grounded to the main panel?



Most panels come with a bar joining the two, which is easily removed. Code requires subpanels to have a ground connection that’s independent of the main panel’s.

Does sub panel wire need to be in conduit?

Re: Subpanel wire run

Individual THHN conductors must be run in conduit–either metallic or non-metallic, flexible or rigid. You could probably use SER instead, as long as it’s sheathed and contains four conductors: one for Leg A, Leg B, neutral, and ground.

What size conduit do I need for 100 amp sub panel?



Installation of 100 amp electric service or subpanel needs a #4 AWG copper wire or #2 AWG aluminum or copper-clad wire inside a minimum 1.25 inch, schedule 40 or 80 PVC electric conduit for underground service.

What size wire is needed for a 50 amp sub panel?

Base Conductor Size

So in your case, if you want to install a 50 ampere panel, you’ll need at least 8 AWG copper conductors.