Troubleshooting in Plumbing: How to Move a Vent Stack

  1. Planning the Move. …
  2. Determine the maximum allowable distance from the fixture that the vent services to the vent. …
  3. Determine if the new position exceeds the allowable length of the vent pipe. …
  4. Check the proposed path of the new vent for obstructions. …
  5. Installing Pipe.

Can a vent pipe be rerouted?

A plumbing vent pipe helps keep this process going by maintaining the air pressure throughout the pipes. But if you’re remodeling a bathroom, repiping a home, or even moving a wall, you may need to reroute your plumbing vent.

How do you reroute a vent?





Quote from the video:
Quote from Youtube video: Make a cross right about here to connect to the existing vent line that vents the shower drain. But the problem is this copper water lines right on the way look at this copper line. So.

Can you have a bend in a vent stack?

Do Plumbing Vent Pipes Need to be Straight? Plumbing vents need to be straight on the vertical. This is necessary to avoid any vapor locks from occurring. When there is a bend in the vent pipe, moisture accumulates and is trapped.

Can a vent stack have a horizontal run?

To answer your specific question, yes, vent pipes can have horizontal runs, as long as there is no possibility of them becoming plugged with water. In other words, any water that gets into the vent pipe opening must be able to run freely all the way to the sewer, without creating a “trap”.

How much does it cost to move a vent?

Depending on the length and size of the duct, as well as whether or not additional labor is involved to maneuver through floorboards and walls, individual duct runs generally cost anywhere from $300 to $1,200, though this is an average.

Can you put an elbow in a vent pipe?





Note: You may have vent piping, but you still cannot use the tight 90-degree elbow — sometimes called a “vent elbow” — if the joint is below the water level, which is usually at the level of the sink.

Can a vent stack be moved?

A: Many DIYers have experienced that “uh-oh” moment at some point in their remodeling escapades. You know, when they gleefully start to tear down a wall and find all sorts of unexpected things going up through and between the wall studs. The fast answer for Suzanne is the vent pipes can be moved.

Can you offset a vent stack?

For this system to function effectively there cannot be any offsets in the waste stack portion. Once the highest branch interval is connected to the stack, the vent portion may contain offsets, provided such offsets are at least 6 inches above the branch interval connection.

Can a vent stack angle?

Tips for Installing Vent Pipes



Vent pipes must be installed so they stay dry. This means that they should emerge from the top of the drainpipe, either straight vertically or at no less than a 45-degree angle from horizontal, so that water cannot back up into them.

How long can a vent pipe run horizontally?



If you have 1 ¼-inch pipe, the horizontal distance of the vent should not be more than 30 inches. For a 1 ½-inc pipe the vent should be 42 inches away at the most while a 2-inch pipe must have a maximum distance of 5 feet.

Can you run a sewer vent out the side of a house?

No problem, as long as the vent meets the criteria listed below. Not directly below a door, openable window, or other air intake opening (of this or any other building). Not within 10 feet horizontally of the above mentioned openings, unless it’s 3 feet above them. Not less than 10 feet from the property line.

How far can a toilet be from a vent stack?

6 feet



According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.

Can a toilet and sink share a vent?

Wet venting is most common in conjunction with toilets and sinks; the drain for the sink is also the vent for the toilet. It can also be used for a variety of other applications but due to the following rules this is the most convenient and common situation to run into.

How far can a sink be from a vent stack?

There is a vent between the sink P-trap and the point where the waste line goes to the main sewer. The vent can’t be more than 2 1/2 feet from the trap if the waste line has a diameter of 1 1/2 inches. The critical distance is 3 1/2 feet if the waste line is 1 1/2 inches.

How far can shower drain be from vent stack?

The maximum distance from a shower trap arm to a vent is usually 5 feet, though some municipalities may allow up to 8 feet.

How far should a vent stack be above the roof?



The International Plumbing Code (IPC), requires plumbing vent pipes to extend vertically at least 152 mm (6 in.) above a roof, per Section 905.5, “Vent Connections and Grades.” Additionally, vent pipes must be at least 305 mm (12 in.) away from a vertical surface.

How far can a vent be from a washing machine?

It prevents the possibility of a vacuum forming which could affect the water draining from your washing machine. If your washing machine is more than 4 feet from the vent stack, you should install a vent to make sure there’s enough room for the machine to drain properly.

How far can a vent pipe be from a tub drain?

A 2-inch-diameter drain can run a maximum distance of 8 feet if builders only look at the table and not the text.

Can you install a toilet without a vent pipe?

Don’t worry if you do not have a vent pipe in your house, or if it is blocked and you can’t fix it. Instead of thinking about massive construction projects, you can use an Air Admittance Valve, well-known as a cheater vent.

How far can the vent be from the trap?



trap, the distance from the weir of the trap to the vent pipe opening “shall not” exceed 30 inches.