Type NM or SE cable installed on the wall of an unfinished basement shall be permitted to be installed in a listed conduit or tubing or shall be protected in accordance with Table E3802.

Can NM cable be exposed in basement?

For example, NM cable could be installed on the surface of an existing plaster- or wallboard-covered wall in a building where NM cable is allowed. It could be installed exposed in a residential garage or in an attic or basement.

Can Romex be exposed in unfinished basement?





Romex is fine when it is inside a wall/ceiling/floor because it is protected from puncture/cuts/etc. but if it is just running along the exposed walls of a basement that is not up to code.

Can I use nm B in the basement?

You can use nonmetallic sheathed cable in basements, as long as you follow a few rules. If you’re using 12 AWG cable, and you’re installing the cable at angles to the joists. You’ll have to pull the cable through bored holes, or along running boards. You cannot staple the cable along the bottom of the joist.

Do basement wires need to be in conduit?

As a general rule, wherever there are exposed wires, a conduit is required. In unfinished basements, wall wiring requires conduits while ceiling wiring does not. In finished basements, usually conduits aren’t required. Conduit is protective tubing that prevents wire damage.

Can Romex touch concrete?

Yes, Romex can pass through concrete without any additional protection, but it should not be exposed to a situation where it may suffer physical damage.

How do you run electrical wire in an unfinished basement?





Quote from the video:
Quote from Youtube video: If it starts and stops and you're not going to finish the basement but you're going to put in a couple circuits here and there for condu coming down the wall just so you can run on your exercise.

Does Exposed Romex need to be in conduit?

Code and common sense both dictate that Romex shouldn’t be left exposed but must run through conduits. If you are running it through the basement or attic (or both), the wire must past through studs or be secured on top of joists or trusses.

Can NM cable be run in conduit?

Yes, NM cable can be in conduit. In fact. NEC calls for it to be in conduit, when protection from physical damage is required.

Can NM cable be exposed in garage?

Exposed NM, NMC and NMS cable are allowed to be run in “one- and two-family dwellings, their attached or detached garages, and their storage buildings” by the National Electrical Code (NEC 334.10 and 334.15).

Can you concrete over cables?



Pouring Concrete Around The Underground Electrical Network Is Not Acceptable.

Can I run Romex through cinder block?

You should be okay when running a wire through a cinder block so long as it’s an underground feeder (UF) wire. You should, under all circumstances, avoid using a non-metallic (NM) wire such as a Romex. If you are wiring a new construction home, you won’t have to break the wall – just drill into it.

Will cement damage electrical cable?

It is not damaging to the cable, but it does mean re-threading is impossible, so any repair involves a chisel.

Does concrete damage PVC cables?



Very little attacks PVC. Heat and sharp bits spring to mind and it’s not clear if you are proposing pouring concrete on PVC cable or what. Consider protection from sharp stones if in floor or if along a wall chase, it may not be necessary.

Can you bury electrical wire in concrete?

Installing Buried UF Electrical Cable



Underground Feeder, UF cable, cannot be run inside concrete.

Can you run electric cables in concrete floor?

A channel can be chased in to the concrete floor and pipe work can be retro fitted in a protective conduit (pipe) and then repaired afterwards. Messy and noisy work and exsisting pipes or cables need to be considered carefully but its not a difficult job.

How do you run cables on a concrete wall?

3 Answers

  1. Run the cable along the walls, often by the skirting boards. The cable can be attached with clips to the wall. …
  2. Run the cables in plastic channels that are attached to the walls. …
  3. Run new conduits in the wall.



Can you run PVC conduit through concrete?

PVC conduit is used in and under concrete slabs. Installing conduit under or in concrete slabs protects the wires from the weight and corrosion of the cement. It also allows future expansion of the electrical system by pulling additional wires through the conduit.