How many amps does my subpanel need?

Subpanel Circuit Breaker Sizing
To calculate the breaker size, simply divide the adjusted wattage by 240 volts to find the rated amperage needed for your subpanel.

Can you run a 100 amp sub panel off a 100 amp main panel?





Let me try and answer some of your questions. First the panels you are looking at that are rated 100A simply means you can use them for any application up to 100A. You can for example add a 60A breaker to your existing panel and protect the new subpanel with a 100A rating.

How many breakers can a 60 amp sub panel have?

Modern 60-amp electrical panels are purpose-built as sub-panels and generally only have 8 to 10 slots available for circuit breakers.

Can you run a 200 amp sub panel off 200 amp main?

Is feeding a 200A sub from a 200A main legit? Yes, and you don’t even need another 200A breaker. The 200A breaker alread present in the panel will suffice, and so you can use a subfeed lug kit as DrSparks advises.

Can I run a 100 amp sub panel off 200 amp main?

Can you add a 100 amp breaker to your main panel? Yes you have 12 slots the double pole breaker will only take 2 slots.

Can a 60 amp breaker feed a 100 amp sub panel?





You can feed a 100 Amp panel with a 60 Amp breaker. Keep in mind that the sub panel needs to be rated above the breaker size.

How many amps can you put on a 200 amp panel?

In general, a 200-amp panel should handle no more than 160 amps at once. It’s important to note that people can have 300 or even 400 amps worth of breakers in a 200A panel, as they don’t use all circuits at the same time. Calculating how many circuit breakers you need is also dependent on your home electrical loads.

How many subpanels can you have on a 200 amp service?

Even though there is no limit on the number of subpanels that you can add to a circuit, it shouldn’t exceed 160 amps when you’re using a 200 amp main panel. Always follow this guide to install subpanels effectively.

What size wire do I need to feed a 200 amp sub panel?

The 250 KCMIL wire is the perfect size wire for 200 amp service because it has 255A ampacity (a minimum of 250A ampacity requirement is satisfied).

Should a sub panel have a ground rod?



Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building.

How many 20 amp breakers can you have on a 100-amp panel?

Typical 100-amp panels have 20 circuits, meaning they can handle 20 full-sized breakers.

How many amps can I put on a 100-amp panel?

For example, a 100-amp service panel could have circuit breakers that add up to more than 200 amps.

What size wire do I need for a 100 amp sub panel?



The cable must have a wire gauge sufficient to the amperage of the subpanel—a 100-amp subpanel requires #4 copper wires or, more commonly, #2 aluminum wires, for example. (Aluminum is often used for feeder cables because the cost is typically much lower than that of copper wires.)

Can I use a main panel as a subpanel?

There’s no problem with having a main breaker in a subpanel. It’s required if your panel is in a separate building and has more than six breakers, but there’s nothing prohibiting it in any other case.

Can a sub panel feed a sub panel?

Answer: Yes. The main electrical service panel is where branch circuits originate.

What is the 6 breaker rule?

The “six breaker throw rule” was a requirement in the National Electrical Code that a service must have have a main disconnect that shuts off all power and it cannot take more than six switch throws to do it, and the main disconnect(s) also must be clearly marked, as in the photo above.

How many breakers can you have in a 30 amp sub panel?



The amount of current that is required for the connected loads can only be supported by a 30 Amp sub-panel. The maximum quantity of branch circuits can be determined with a load calculation. Two 15amp breakers or one 15amp and one 20amp can be used on a 30amp circuit.