How do you reset the primary control on a Honeywell oil?

Control is in Hard Lockout. Hold “i” for at least 2 seconds to reset. Hold the “i” button longer than 10 seconds to return to Standby. If QUIT is selected, an “i” button press displays the Re-baseline option.

What are the three things the primary control is responsible for?





The primary control has three main functions: 1. To respond to the thermostat 2. To respond to the limit control 3.

How do you test a primary control on an oil burner?

PRIMARY CONTROL LOCKOUT- Diagnostic Procedure



Disconnect the nozzle line and reposition it to pump oil into a container. Tighten the flare connection at the pump or delayed oil valve discharge fitting. Verify that there is a call for heat.

How do you wire a primary control?

Quote from the video:
Quote from Youtube video: Control connect a new wire to terminal number four on the uc-1. And connect it with the original wire attached to the burner motor terminal on the 7184.

How do I reset my Honeywell boiler control?

Resetting a Honeywell Thermostat

  1. Power off the thermostat and remove the batteries.
  2. Put the batteries in the wrong way, with negative to positive and positive to negative.
  3. Wait ten seconds and put them back in the correct way.
  4. Your thermostat will be reset to factory settings.





What does hard lockout mean on a Honeywell oil primary control?

Hard Lockout: Caused by a failure internal to the control or by a system fault such as flame out of sequence. A Hard Lockout will result in a no heat condition. To reset from Hard Lockout press and hold the “i” button for 2 seconds.

What is an example of primary control?

An example of a primary control item is: “I think my success depends on what I do and how hard I work.” An example of a secondary control item is: “I agree with those who think one should associate with strong and successful people.” These items concern examples of vicarious or illusory control; Seginer et al.

What would the symptoms be of a dirty CAD cell?

If the cad cell fails, or more likely if a dirty oil burner flame soots up the face of the cad cell device, the soot blocks view of the flame and cad cell resistance will increase. (That’s why at zero flame and when it’s dark in the combustion chamber the cad cell will read infinite resistance.)

What is Number 2 fuel oil?



2 fuel oil has a winterized variety known as “home heating oil winter blend.” This blend takes No. 2 heating oil and combines it with No. 1 heating oil to make it less viscous and easier on your furnace or boiler.

What does a interrupted ignition primary control mean?

What does a interrupted ignition primary control mean. It interrupts the ignition transformer. ____________________ employs an electrode spark for a brief period at the beginning of the burners run cycle. Once a flame is established, the spark stops. Interrupted ignition.

What is a good reading when the CAD cell eye is in darkness?

The cad cell in darkness has a very high resistance to the flow of electrical current. Yet, in the presence of visible light, it has a very low resistance. For a properly adjusted burner, during operation, the cad cell resistance should be approximately 300-1000 ohms, but not more than 1600 ohms.

What causes oil furnace to trip?



Common problems can include a dirty CAD cell, faulty burner or fuel pump, blocked oil nozzle, loose electrical connections and more — all of which are beyond the scope of a home repair. A professional will have the tools and expertise necessary to pinpoint the issue and suggest appropriate repairs.

Why do I have to keep hitting the reset button on my oil furnace?

If you have a gas or oil furnace, the reset button may trip if you are out of fuel. This fix is as simple as making sure there is fuel in either the gas or oil tank. If this is the case, when you call for a refill, make sure you let them know that the tank is empty and the tank will need to be primed.

What would cause a furnace not to kick on?

If your furnace is not turning on you should first check if the filter is clean. Dirty filters cause insufficient airflow and can prevent the furnace from starting. Other reasons it won’t start can stem from improper thermostat settings, forgetting to turn on the gas line, or faulty pilot light.

What should be done if a furnace with a tripped primary control has oil is in the combustion chamber?

What should be done if a furnace with a tripped primary control has oil is in the combustion chamber? Clean out the oil before firing the furnace.

How many times can I hit the reset button on my furnace?



Don’t hit “reset” more than twice. The process pumps oil into the burner chamber, where it can accumulate if you have no ignition. Then when the furnace finally does start, it can do so explosively. So if the button won’t reset, or quickly pops up again, it’s time to call a professional repair service.

What might be the problem if the furnace runs but with short cycles?

A short cycling furnace can cause your home heating system to break down prematurely, which can be a big problem during the winter months. If your furnace is short cycling and you can’t seem to get the problem under control, contact the heating contractors at a professional furnace repair service today.

What are some of the problems that occur with oil burners?

Common Problems That Homeowners Experience With Oil Furnaces

  • It Doesn’t Turn On. A furnace not turning on is one of the most common problems with oil furnaces. …
  • Not Enough Heat. …
  • Produces Too Much Smoke. …
  • High Fuel Consumption. …
  • No Flames. …
  • It Goes Off. …
  • Oil Furnace Makes Odd Noises. …
  • Produces Strange Odors.

Why does my oil burner keep running?

If your furnace is constantly running, check the settings on your thermostat; if it is set to “on,” switch to “auto” and see if the problem goes away. Check your thermostat – If switching from on to auto didn’t fix the problem, check your thermostat for things like frayed wires or worn batteries.

Why does my oil burner keep turning on and off?



So, if your furnace keeps turning off and on too quickly, your thermostat might be malfunctioning or broken. There are several things that could be causing your thermostat to not work properly. The wiring could be old and need replacing, it might need new batteries, or it could be the location of your thermostat.