Can no hub couplings be used underground?

A: Hubless cast iron soil pipe and fittings are allowed for underground installations by all of the model codes.

What size is sump pump discharge pipe?





1.5 inches

Most sump pumps have a recommended discharge size of 1.5 inches. The line must be run to the outside of the house.

How do you extend a sump pump discharge pipe?

Quote from the video:
Quote from Youtube video: Whether that's two pvc pipes coming together and that fails over time or the ground heaves and cracks the pipe. Then water starts coming out and small little roots find their way into the pipe.

Can you use a Fernco coupling in a wall?

Fernco (Rubber) fittings are not approved in wall framing unless they have a metal sheathed hose clamp assembly covering the entire fitting as part of the design, Which limit them to straight couplings or reducing couplings.

Where can I use no hub coupling?





Quote from the video:
Quote from Youtube video: They can be especially helpful when the piping is in a hard-to-reach spot or the pipe is unable to be moved in odd direction to allow the repair to be made with the solvent.

What are no hub couplings used for?

Intended for use with DWV systems, no-hub couplings are used to join cast iron soil pipe that does not have the traditional Hub and Spigot. They are normally installed using a torque wrench. Generally, they have more clamps and provide a greater band load than standard no-hub couplings.

How long can the discharge pipe be for a sump pump?

Using a properly sized pipe for discharge will ensure that the sump pump will perform as the manufacturer intended. Installing discharge pipe of a larger size is not a huge problem and is in fact recommended for longer runs of pipe, typically 20 feet or more.

Do I need a 1/3 or 1/2 HP sump pump?

There is no “correct” size. The horsepower requirement for a house is determined by the area of drainage connected to the sump, the depth to groundwater, the depth of the basement and many other factors. A 1/3 horsepower (hp) pump is satisfactory for most houses, but a 1/2 hp pump doesn’t cost that much more.

How do you connect two sump pump hoses?



Quote from the video:
Quote from Youtube video: But if you just want a straight connection you can't find it. So what we need is female threads on both ends the pipe in between.

Can Fernco be used on sump pump?

Features. INSTALL SUMP PUMPS WITH CONFIDENCE: The Fernco QwikFlex sump pump installation kit makes connecting any new sump pumps quick and easy. NO FUSS. NO MESS.

Do flexible couplings meet code?

They’re accepted by a number of codes — including the Uniform Plumbing Code and the International Plumbing Code — for both above- and below-grade use. I’ve installed many of these couplings above and below grade and have never encountered a problem.

Can flexible couplings be used underground?



Flexible Transition Couplings for Underground Piping Systems



So as it turns out, these fittings are indeed rated for direct burial.

Are Fernco fittings legal underground?

Can you bury Fernco couplings in concrete? Here, Fernco, if you are referring to the all rubber coupling with 2 hose clamps, can ONLY be used underground. But, it has to be outside the building.

Can Fernco fittings be buried?

A unshielded fernco should never be buried. Instead use a shielded coupling that is meant for direct burial in dwv.

Is flexible PVC rated for underground use?

You should use only rigid PVC pipe for the plumbing in your inground swimming pool. Even though it’s more difficult to install, it’s much stronger than flexible PVC pipe, which isn’t rated for underground use at all. Flexible PVC is easy to crush or puncture, and bugs like termites can chew through it.

How do you connect PVC to flexible tubing?



Quote from the video:
Quote from Youtube video: Let's put cement on the fitting and the PVC pipe and inside of both ends of the coupler. I'm going to put the coupler on the pipe. First little quarter turn for a good seal.

Is Schedule 40 PVC good for underground?

Schedule 40 rigid PVC conduit, elbows, that are specifically marked for underground use are suitable for use underground only by direct burial or encasement in concrete. The UL listing says both 80 and 40 can be used in both above and underground installations.

How long will schedule 40 PVC pipe last underground?

The Water Research Foundation reported that 100 years is a conservative estimate for a properly designed and installed PVC pipe.

Can I use Schedule 40 PVC for drain?

Schedule 40 is ideal for above-ground vent lines and sewer lines in homes and has a thinner wall thickness than schedules 120 and 80.

Will PVC pipe freeze underground?



Debris and Weather Damage to Underground PVC



For PVC piping systems that are buried underground, sunlight won’t be a problem, but debris, soil movement, and freezing temperatures may be.