For overhead cable pulls, 3M recommends a gel or wax-based lubricant such as the colorless, non-staining WL polymer gel, or WLX wax-based lubricant. “For hot environments, the wax-based lubricant is the best choice,” says Vanden Branden.

What can I use for wire pulling lube?


Quote from Youtube video: Use a thick gel lubricant like poly water jay poly water plus silicon or Dyna blue to get the best. Results. These lubricants are easy to pick up with your hands.

How do you lubricate wire through conduit?





Quote from the video:
Quote from Youtube video: So i'm going to squirt some into my hand like so and this is a this is a wax based lubricant. Okay it's easy to wash off your hands but it doesn't wash off the cable very easily.

Can you use dish soap as wire lube?

Dawn dish soap is a great pull lube the only problem is it drys out after a while and trying to pull the wires out at a later date is almost impossible, but this also happened with commercial lubes, they do make non drying lubes, but in a residential I usually save a few bucks as these are not pulled as often as

Can you use Vaseline to pull wire?

It’s absolutely the best wire-pulling lube I’ve ever used. I was skeptical at first because of the price per ounce, but you use very little per pull so a single can goes a long way.

What is cable pulling lubricant made of?

Most lubricants are approximately 80 to 90% water plus other additives to create lubricity. Lubricant additives include wax, polymer, silicone, fluorinated ethylene propylene (FEP), or other chemicals specifically formulated for specific applications.

What is silicone lubricant used for?





Silicone spray lubricant lubricates metals that fasten together and move, including cables, bearings, springs, hinges, hoses, latches and much more. Silicone sprays are an effective way of lubricating metals from friction.

How do you use KY jelly?

Apply the desired amount of lubricant directly from the tube to the skin or to a condom. Reapply as required. If skin, penile, or vaginal irritation develops, stop using KY Jelly immediately and wash the area with water. Seek medical attention if the irritation persists.

What is all purpose anti rust lubricant?

All-Purpose 4-Way™ is formulated to lubricate, penetrate, and displace moisture, leaving parts with a protective anti-rust film. This lubricant protects metal parts which helps eliminate pounding and breakage during disassembly. All-Purpose 4-Way has no CFCs, chlorinated solvents, or silicones.

How do you get a stuck wire out of conduit?

Quote from the video:
Quote from Youtube video: And simply push it in as you're going push in as you're going i'm sorry about that. And then i mean it may not get the first time and i get it first few times but sometimes it does.

How do you get fish tape out of conduit?



The fish tape method works as follows: Feed the tape: Feed the end of the tape into the end of the conduit you wish to pull from. Continue pushing the tape through the conduit and unwind the spool as you go. When the end of the fish tape emerges from the end of the conduit, stop feeding the tape.

Can you pull Romex through conduit?

No, you can not run your Romex wiring in conduits.

What is difference between Thhn and THWN?

The main difference between these two standards is their maximum temperature in wet locations. THWN has a maximum temperature of 90°C in dry and wet locations, whereas THHN wire can only be used in temperatures as high as 75°C in wet locations. However, most of these wires, so you can use THHN and THWN interchangeably.

How many 90s can you pull wire through?



Moderator. In one conduit run you can have as many 90’s as you want as long as there are pulling points so that no section of the run contains more than 360 degrees.

How many degrees can you have in a conduit run?

There shall not be more than the equivalent of four quarter bends (360 degrees total) between pull points, for example, conduit bodies and boxes.

How many inches do you deduct for a 90 degree bend?

The most common deducts are 5″ for ½” conduit, 6″ for ¾” conduit and 8″ for a 1″ bender. It is a function of the curvature radius of the bender and cannot be changed. The deduct for your bender should be stamped on the bender.