Can a shower and toilet share a vent?

Wet vents are typically used when plumbing a bathroom group. So yes the shower can also be vented by the wet vent along with the toilet. There is one major stipulation when wet venting multiple fixtures when a toilet is one of them: the toilet must be the last fixture connected to the wet vent.

Can two toilets share the same vent?





Most houses have more than one toilet, and if they are on the same side of the house, their waste lines can usually tie into the same stack. If they are on opposite sides, however, each may need its own stack. Since the stacks must be vented, this would mean two vent openings on the roof.

Can you vent a toilet from behind?

There are many different ways to vent your fixtures, and you’re going to want to cater to the factors present in your bathroom. The most common configuration is to feed 2″ PVC down from the ceiling within the wall behind the toilet. The vent pipe connects into the toilet drain pipe.

Can you vent a toilet and sink together?

Wet venting is most common in conjunction with toilets and sinks; the drain for the sink is also the vent for the toilet. It can also be used for a variety of other applications but due to the following rules this is the most convenient and common situation to run into.

How far away can a vent be from a toilet?

6 feet





According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.

Does each toilet need its own vent?

“Does a toilet need a vent?” And the answer is yes, your toilet has to have a vent. For more information on the great importance of plumbing vents, read our plumbing vent article here. And the size of this vent pipe depends on your local plumbing code.

Can toilets be installed back to back?

Proper Double Fitting For Bulk Flush Toilets
Homes built before 1965 may use a double sanitary tee to accommodate drainage from two toilets that are installed back-to-back. The double tee may not be effective for installations using bulk performance flush toilets (Pressure Lite®, Class Five®, and Class Six®).

Can you vent two bathrooms together?

Well, you can’t! You’d often blow air from one bathroom into the other, and local building inspectors wouldn’t approve it. But while you can’t have two fans with one vent, you can make one fan and one vent serve two bathrooms.

Can two plumbing fixtures share a vent?



Yes they both can share a vent. The distance between yours is 4′ if I read it correctly so you are well within the distance between the vent and fixtures so you should be golden unless your local code has some bizarre requirements.

Do plumbing vents have to go through the roof?

It does not have to go through the roof. From the plumbing code (I have the 2003 edition), P3103: It must not be less than 4 feet directly beneath a door, openable window or other air intake of the building or adjacent building.

Can a toilet and shower share the same drain?

The general answer is that the showers and toilets can use the same drain, but they should not be sharing the same waste trap arm. There are other factors to consider as well, such as whether your drains lead to the main sewer line, or if there are septic tanks that are used in your city or town.

How far can vent be from shower drain?



The maximum distance from a shower trap arm to a vent is usually 5 feet, though some municipalities may allow up to 8 feet.

Does plumbing vent go before or after trap?

The simple answer is if your trap from the fixture cannot see the vent then it is installed wrong. We must always keep the vent connection above the trap weir to prevent siphoning and keep proper pressures on both side of the trap.

Can a vent be upstream from a toilet?

A toilet vent can be upstream. The purpose of the vent pipe is to allow the sewer’s gases to escape from the house’s roof rather than inside the house. A vent also allows oxygen to enter into the sewer pipes, which allows the waste to break down and prevents clogging.

Can a plumbing vent run horizontal?

2. Can Vent Pipes be Horizontal? There is no problem with running your vent pipes horizontally as long as you remember that there should be a minimum clearance of 6 inches above the spill line.

Does a plumbing vent pipe have to be vertical?



Do Plumbing Vent Pipes Need to be Straight? Plumbing vents need to be straight on the vertical. This is necessary to avoid any vapor locks from occurring. When there is a bend in the vent pipe, moisture accumulates and is trapped.

Where should plumbing vent be located?

Vent pipes must be installed so they stay dry. This means that they should emerge from the top of the drainpipe, either straight vertically or at no less than a 45-degree angle from horizontal, so that water cannot back up into them.

Can plumbing vents have bends?

One should avoid bends and turns in the vents to ensure that there is no possibility of a trap. If it is being placed horizontally, ensure that it is at an angle no more than 45 degrees. Essentially, the vent pipe needs to be dry at all times.

How many plumbing vents can be tied together?

You can usually tie up to eight fixtures to a single stack, but local codes differ, so it’s a good idea to check.

How far can a vent be from a fixture?



The only vertical pipe of a combination drain and vent system shall be the connection between the fixture drain and the horizontal combination drain and vent pipe. The maximum vertical distance shall be 8 feet (2438 mm). 912.2.