Avoid a 90 degree elbow immediately off the duct connector. An installation that has a 90-degree elbow immediately after the fan exhaust port will cause air to flow back into the fan.

How long can the duct be for a bathroom fan?

Minimum vent fan duct lengths



Fantech recommends a minimum of eight feet of insulated flex duct between the exhaust inlet register or grille and the fan motor. The company does not cite a maximum exhaust duct length.

What is the proper way to vent a bathroom exhaust fan?





The fan exhaust must vent directly to the exterior of the home. Do not put the vent termination in a roof overhang or soffit. Don’t put it on a wall near or under a roof overhang. The moist air that’s belched out by the fan can be sucked right up into the open soffit vents and be drawn into your attic.

Can a bathroom exhaust fan be mounted vertically?

As a general rule, bathroom exhaust fans can be installed vertically/on the wall. Some of these exhaust fans even put that mounting position as an option in the manual. Though you should always consult the manual before making the decision to install it vertically, many can be installed in this position.

Does a bathroom need a fan by code?

As a general rule, a bathroom fan is not required by code, if there is an openable window in the bathroom. While not required by code, it is always best to install a bathroom fan to protect the building from moisture damage. An exhaust fan will ventilate the bathroom much more effectively compared to a window.

Can I use flex duct for bathroom fan?

Flexible duct is perfectly acceptable for a bathroom fan.

Can you use PVC pipe to vent a bathroom fan?





PVC piping is an excellent material to use for venting your bathroom fan as long as the correct type of pipe is used. PVC creates a better seal than metal, so you won’t experience any problems with leakage as you could with using metal ducting pipes.

Is it better to vent bathroom fan through roof or soffit?

Whether it’s new construction or a remodel, a bathroom vent should always vent through the roof instead of an eave, overhang, or soffit. The point of a bathroom exhaust vent, or any vent really, is to remove hot, moist air from the house.

Can you vent bathroom fan through gable vent?

When venting a bathroom exhaust fan, make sure to vent the air to the outside, rather than into your attic where it can cause mold and mildew to form. Options for venting a bathroom exhaust fan include (best to worst): Through the roof or an exterior gable wall.

Can you vent a bathroom fan through side of house?

Can a Bathroom Fan Vent through a Side Wall? You can vent your bathroom fan through a sidewall of your house. In situations where you don’t have access to the eaves of your house and you don’t want to go through the roof, a sidewall is your best option.

Is it against code to vent bathroom into the attic?



The Code of Bathroom Exhaust Fans



Air shall not be exhausted into an attic (except whole house ventilation), soffit, ridge vent or crawl space.

Is it OK to vent bathroom fan through soffit?

A bathroom fan can be vented through soffit so that the warm air from the bathroom comes out through it and goes outside. However, It is important to keep in mind it can not be vented into the soffit, as this will lead moisture back into the attic.

Does a bathroom exhaust fan need to be on a GFCI?

Although the National Electrical Code (NEC) does not have a requirement for a bathroom exhaust fan to be GFCI protected, it is often specified by the manufacturer in the installation instructions when the fan is over a tub or shower.

How do you attach a flex duct to an exhaust fan?




Quote from Youtube video: Right over the top of it and you're gonna hear it crimp down and clip it nice and tight.

Can you use dryer duct for bathroom vent?

A bathroom fan and a dryer should never share the same vent. International building code states that dryer vent exhaust systems must be separate from all other systems and must expel moisture out of the house through a dedicated vent. This is because of the potential hazards associated with improper dryer venting.

Can you run 2 exhaust fans 1 duct?

Well, you can’t! You’d often blow air from one bathroom into the other, and local building inspectors wouldn’t approve it. But while you can’t have two fans with one vent, you can make one fan and one vent serve two bathrooms.

Can you tie bathroom exhaust into plumbing vent?

The answer is no way! Sewer gas is explosive and could settle back into your exhaust fan which has an electric motor that is not rated for explosive gases.

Can 2 bathroom fans share a vent?



Bathroom fans can share a common vent. Both fans must be of similar capacity and have back-draft dampers installed. The duct must be over-sized by one inch for every additional fan added to the system.

Can kitchen and bathroom Share vent?

Simply put, NO. You cannot (by code) and should not (by practical reasoning) share exhaust venting between a kitchen exhaust and a bathroom exhaust fan.

How do you vent a bathroom with no outside access?

Installing a ceiling vent is probably the most efficient way to ventilate a bathroom with no outside access. A ceiling vent is a unique machine that allows air to escape from the bathroom. In other words, it’s a machine that, like an open window, allows moisture to escape from your bathroom.