Does switch box need neutral wire?

Neutrals. When wiring lighting circuits supplied by a grounded general-purpose branch circuit, the 2011 NEC now requires you to provide a neutral conductor at nearly every switch point [404.2(C)]. The purpose for this is to complete a circuit path for electronic lighting control devices, such as occupancy sensors.

How do you wire a switch to a neutral wire?





Quote from the video:
Quote from Youtube video: And we've got our ground wire which would connect to the unshielded copper wires. Right here underneath you red wire nut. So that light switch this one's available from us when our smart home comm.

What do you do if you don’t have a neutral wire?

If your switch box doesn’t have a neutral wire, you have two options. First, you can have an electrician install one. Our electrician claimed it’s not difficult work, but they’ll need to get behind your walls.

Where is the neutral wire in a switch box?

Remove the wall plate of the existing switch by either snapping it off or unscrewing it. Unscrew the existing switch from the electrical box and slowly pull it out just enough to reveal the wires connected to it. If you see a white wire, or a group of them, then you have neutral wiring.

Do you need to run a neutral to a switch?

So if you’re going to run a neutral, you’ll want to run it from the light to the switch. Some electronic switches, like timers, operate without a neutral, using the safety ground for the return current for the electronic controls. If there’s a safety ground present, that’s probably the easiest solution.

Can you have a neutral at a light switch?





It’s important to note that your home may be wired differently to this, especially in newer houses and in mainland Europe where the incoming power goes to the switch first and then to the light. We refer to this as “switch-first wiring” which means you do have a neutral at the switch.

Can you switch the neutral wire?

The neutral wire is connected to ground at the breaker box, which is connected to physical ground nearby. If you switch the hot line and leave the neutral, then the whole device will be at neutral potential. That’s OK. If you switch the neutral, then the whole device will be at hot potential.

Does neutral wire carry current?

The neutral wire will be connected to the earth ground, the color of the neutral wire could be grey or white. During normal operations, the neutral wire will carry current. We can see neutral in most of the electrical equipment, mostly in non-linear loads.

Can I use ground as neutral?

A ground is not a neutral period. The last thing you want is the chassis of your washer as a current carrying conductor. If your house has a bonded neutral and ground then it should be at only at one connector and that is your circuit breaker panel and nowhere else.

Is a neutral wire the same as a ground wire?



While a ground wire and neutral wire are connected, they serve different functions in the overall electrical scheme. The neutral wire is part of the normal flow of current, while the ground wire is a safety measure in case the hot wire comes in contact with the metal casing of an appliance or other shock hazard.

What color wires are neutral?

white wire

The white wire is the “neutral” wire, it takes any unused electricity and current and sends it back to the breaker panel.

What is the point of the neutral wire?



Neutral wire carries the circuit back to the original power source. More specifically, neutral wire brings the circuit to a ground or busbar usually connected at the electrical panel. This gives currents circulation through your electrical system, which allows electricity to be fully utilized.

Can the neutral wire shock you?

You get shocked when current flows through your body. Often, the neutral wire is very close to ground potential, and you are too. So, often, there is not enough voltage to give you a shock.

Can a neutral wire be used as a hot wire?

Furthermore, neutral wires can be used as a hot wire if both ends are clearly marked with colored electrical tape (black or red) that corresponds to its repurposed function. In either case, handle them the same way you would a hot wire, and take the same safety precautions.

Can ground and neutral be on the same bar?

The answer is never. Grounds and neutrals should only be connected at the last point of disconnect. This would be at main panels only.

Can I add a neutral bar to a panel?



You CANNOT add a neutral bus.



So the neutral bars have thermal considerations ground bars do not, as well as, you don’t want current to normally be present on the panel chassis, which is grounded. So you cannot add additional neutral bars, but they provided enough neutral slots for your needs, so you are all set.

What happens if neutral touches ground?

Connecting the neutral to the ground makes the ground a live wire. The neutral carries the current back to the panel. But the ground doesn’t carry a charge, not unless something has gone wrong (such as a short circuit) and it has to direct wayward electricity away from the metal case of an appliance.

Do subpanels need to be bonded?

Rule #3: In a subpanel, the terminal bar for the equipment ground (commonly known as a ground bus) should be bonded (electrically connected) to the enclosure. The reason for this rule is to provide a path to the service panel and the transformer in case of a ground fault to the subpanel enclosure.

Does a subpanel need its own ground rod?

Yes, any sub panel outside of the main building requires it’s own ground rod and a ground wire back to the main building. And yes, a sub panel in the same building as the main does not need a ground rod – only the ground wire.

What happens if you bond neutral and ground in subpanel?



With ground and neutral bonded, current can travel on both ground and neutral back to the main panel. If the load becomes unbalanced and ground and neutral are bonded, the current will flow through anything bonded to the sub-panel (enclosure, ground wire, piping, etc.) and back to the main panel. Obvious shock hazard!