Can I use SER cable to feed a subpanel?

SER is a perfect cable for feeding power to your sub-panel, and, depending on the amount of amps their sub-panels are handling (we’ve seen everywhere from 50 amp to 200 amp sub-panels being serviced), our customers are using all sizes of SER as a sub-panel feeder.

Does Ser cable need conduit?





Technically SE cable ran indoors is treated as NM cable…. I’d recommend metallic flex though if a conduit is to be used. Show activity on this post. SER is fine.

How do you install SER cable?

Quote from the video:
Quote from Youtube video: It's got all those green screws in it you can double tap those babies you can put two in each one of those that's why it's shorter. But the neutral bus you can only put one wire.

Where can se cable be used?

Type SE cable is often used for interior wiring to supply heating and cooling equipment, appliance branch circuits and for feeders to subpanels.

Can you run Ser cable through conduit?

SE cables simply can’t be buried, conduit or no conduit.

What is SER cable used for?





SER cable is known as aluminum service entrance cable which is a type SE (service entrance), Style R (reinforcement tape) cable that is commonly used to deliver power from the service drop down to the meter base, and then from the meter base to the distribution panel board.

What size aluminum wire do I need for 100 amp service?

For 100 AMP service, you’ll need a #4 AWG copper wire or #2 AWG aluminum or copper-clad wire. Make sure to limit your voltage drop to 3% regardless of distance.

What is the difference between SE and Ser cable?

Basically, SER is a round service electrical cable that typically has up to four conductors and a bare neutral. The cable is designed to use above the ground in feeder panels and branch circuits. SEU is an unarmored Style U flat service electrical cable with two-phase conductors and a concentric neutral.

Can you run Ser cable outside?

Senior Member. Sure you can. Not sure why some think you can’t…

When used as an outside service entrance conductor SE cable must be secured?



When used as a branch circuit or feeder, Type SE cable must be supported and secured in accordance with 334.30 at intervals not exceeding 4½ feet and within 1 foot of every outlet box, junction box, cabinet or fitting.

What is #2 Ser cable rated for?

600 volts

The cable is rated at 600 volts and 90_C for use in wet and dry locations. SER cables are LEAD FREE and RoHS compliant.

How far can you run service entrance cable?



Most AHJ have made rules on what is acceptable for the distance allowed. Many are in the 3 to 5 feet of conductor range, from what I understand from some that have posted on this site, some places will not let you enter a building at all and your service disconnect must be outside.

Can direct burial cable be put in conduit?

Direct-burial cable does not always need conduit, but it can be run inside the conduit to add additional protection to any electrical system. This type of cable is designed to withstand direct exposure to the soil and moisture and is rated for wet, dry, and damp environments.

What kind of cable do I need for a 200 amp service?

Installation of 200 amp electrical service needs a #2/0 AWG copper wire or #4/0 AWG for aluminum or copper-clad wire inside a minimum of 1.5 inches, schedule 40 or 80 PVC conduit for underground service.

Can I use PVC conduit for service entrance?

It can be conduit or direct burial. Above ground to 18″ below ground it would need to be schedule 80 PVC or could be rigid metallic or IMC. Below 18″ schedule 40 would work. If you go with direct burial it needs to be 24″ with the sections above 24″ protected by schedule 80 or rigid metallic or IMC as a quick overview.

How do you connect PVC conduit to electrical panel?



Steps to Connecting the Conduit to the Electrical Box

  1. Power off. First, the number one safety protocol before working on electrical maintenance is switching off the main breaker. …
  2. Cut the conduit. …
  3. Smoothen it out. …
  4. Install the fittings. …
  5. Apply the PVC cement. …
  6. Connect the pipe and the box. …
  7. Fish the wirings through.


Where is PVC conduit not allowed?

Ambient temperature — PVC conduit isn’t permitted to be installed if the ambient temperature exceeds 50°C (122°F) [Sec. 352.12(D)].

Can I use white PVC for electrical conduit?

Tested for Pressure



One of the biggest differences between plumbing PVC pipe (here) and PVC electrical conduit is that PVC pipes are pressure tested and PVC conduit isn’t. This means that PVC pipe and PVC conduit cannot be used interchangeably.

Should I glue PVC electrical conduit?



PVC Conduit Doesn’t Need Primer



Some PVC pipes require primer, but you don’t need to use primer when gluing conduit and fittings. Home centers usually sell the appropriate glue/cement near the the PVC conduit and fittings.

Can you run Romex in PVC conduit?

No, you can not run your Romex wiring in conduits.